E-Mail Us Close
Please note that this email should only be used for feedback and comments specifically related to this particular medical policy.
  
Horizon BCBSNJ
Uniform Medical Policy ManualSection:Surgery
Policy Number:111
Effective Date: 04/12/2016
Original Policy Date:04/27/2010
Last Review Date:04/14/2020
Date Published to Web: 05/18/2010
Subject:
Keratoprosthesis

Description:
_______________________________________________________________________________________

IMPORTANT NOTE:

The purpose of this policy is to provide general information applicable to the administration of health benefits that Horizon Blue Cross Blue Shield of New Jersey and Horizon Healthcare of New Jersey, Inc. (collectively “Horizon BCBSNJ”) insures or administers. If the member’s contract benefits differ from the medical policy, the contract prevails. Although a service, supply or procedure may be medically necessary, it may be subject to limitations and/or exclusions under a member’s benefit plan. If a service, supply or procedure is not covered and the member proceeds to obtain the service, supply or procedure, the member may be responsible for the cost. Decisions regarding treatment and treatment plans are the responsibility of the physician. This policy is not intended to direct the course of clinical care a physician provides to a member, and it does not replace a physician’s independent professional clinical judgment or duty to exercise special knowledge and skill in the treatment of Horizon BCBSNJ members. Horizon BCBSNJ is not responsible for, does not provide, and does not hold itself out as a provider of medical care. The physician remains responsible for the quality and type of health care services provided to a Horizon BCBSNJ member.

Horizon BCBSNJ medical policies do not constitute medical advice, authorization, certification, approval, explanation of benefits, offer of coverage, contract or guarantee of payment.

__________________________________________________________________________________________________________________________

A keratoprosthesis, consisting of a central optic held in a cylindrical frame, is an artificial cornea intended to restore vision to patients with severe bilateral corneal disease for whom a corneal transplant is not an option. The keratoprosthesis replaces the cornea that has been removed and is held in place by the surrounding tissue. Various biologic materials are being investigated to improve integration of the prosthetic into the eye.

Populations
Interventions
Comparators
Outcomes
Individuals:
· With corneal blindness who have failed or are not candidates for corneal transplantation
Interventions of interest are:
· Boston Keratoprosthesis
Comparators of interest are:
· Penetrating keratoplasty
Relevant outcomes include:
· Change in disease status
· Morbid events
· Quality of life
· Treatment-related morbidity
Individuals:
· With corneal blindness who have failed or are not candidates for corneal transplantation
Interventions of interest are:
· Keratoprosthesis using the AlphaCor device
Comparators of interest are:
· Penetrating keratoplasty
Relevant outcomes include:
· Change in disease status
· Morbid events
· Quality of life
· Treatment-related morbidity
Individuals:
· With corneal blindness who have failed or are not candidates for corneal transplantation
Interventions of interest are:
· Osteo-odonto-keratoprosthesis
Comparators of interest are:
· Penetrating keratoplasty
Relevant outcomes include:
· Change in disease status
· Morbid events
· Quality of life
· Treatment-related morbidity

Background

Cornea

The cornea, a clear, dome-shaped membrane that covers the front of the eye, is a key refractive element of sight. Layers of the cornea consist of the epithelium (outermost layer); Bowman layer; the stroma, which comprises approximately 90% of the cornea; Descemet membrane; and the endothelium.

Treatment

The established surgical treatment for corneal disease is penetrating keratoplasty, which involves making a large central opening through the cornea and then filling the opening with a full-thickness donor cornea. In certain conditions, such as Stevens-Johnson syndrome, ocular cicatricial pemphigoid, chemical injury, or prior failed corneal transplant, survival of transplanted cornea is poor. The keratoprosthesis was developed to restore vision in patients for whom a corneal transplant is not an option.

Keratoprosthetic devices consist of a central optic held in a cylindrical frame. The keratoprosthesis replaces the section of the cornea that has been removed, and, along with being held in place by the surrounding tissue, may be covered by a membrane to further anchor the prosthesis. A variety of biologic materials are being investigated to improve the integration of prosthetic corneal implants into the stroma and other corneal layers.

The Dohlman-Doane keratoprosthesis, most commonly referred to as the Boston Keratoprosthesis (KPro), is manufactured under the auspices of the Harvard Medical School-affiliated Massachusetts Eye and Ear Infirmary. The Boston type 1 KPro uses a donor cornea between a central stem and a back plate. The Boston type 2 prosthesis is a modification of the type 1 prosthesis and is designed with an anterior extension to allow implantation through surgically closed eyelids. The AlphaCor, previously known as the Chirila keratoprosthesis (Chirila KPro), consists of a polymethylmethacrylate (PMMA) device with a central optic region fused to a surrounding sponge skirt; the device is inserted in a 2-stage surgical procedure.

Autologous keratoprostheses use a central PMMA optic supported by a skirt of either tibia bone or the root of a tooth with its surrounding alveolar bone. The most common is the osteo-odonto-keratoprosthesis, which uses osteodental lamina derived from an extracted tooth root and attached alveolar bone that has been removed from the patient’s jaw. Insertion of the osteo-odonto-keratoprosthesis device requires a complex staged procedure, in which the cornea is first covered with buccal mucosa. The prosthesis itself consists of a PMMA optical cylinder, which replaces the cornea, and is held in place by biologic support made from a canine tooth extracted from the recipient. A hole is drilled through the dental root and alveolar bone, and the PMMA prosthesis is placed within. This entire unit is placed into a subcutaneous ocular pocket and is then retrieved 6 to 12 months later for final insertion.

Hydroxyapatite, with a similar mineral composition to both bone and teeth (phosphate and calcium), may also be used as a bone substitute and as a bioactive prosthesis with the orbit. Collagen coating and scaffolds have also been investigated to improve growth and biocompatibility with the corneal epithelial cells, which form the protective layer of the eye. Many of these materials and devices are currently being tested in vitro or animal models.

Regulatory Status

In 1992, the Boston KPro (Dohlman-Doane keratoprosthesis; Massachusetts Eye and Ear Infirmary) was approved by the U.S. Food and Drug Administration through the premarket approval process for use in patients with severe corneal opacity. The device is used when standard corneal transplant has failed or would be unlikely to succeed. There are 2 types of Boston KPro. Type 1 is used in eyes when eyelids, blink mechanism, and tear film are intact. Type 2 is used with severe dry eye and in eyes with mucosal keratinization and obliteration of normal conjunctival fornices.

In August 2002, the AlphaCor® (Chirila Keratoprosthesis) was cleared for marketing by the Food and Drug Association through the 510(k) process. The Food and Drug Administration determined that this device was substantially equivalent to the Dolman-Doane keratoprosthesis. The AlphaCor® device is indicated as a keratoprosthesis in adults with corneal opacity when standard penetrating keratoplasty with donor tissue is not suitable, when patients have declined standard penetrating keratoplasty, or when adjunctive procedures to prevent graft rejection are contraindicated.

Related Policies

  • Implantation of Intrastromal Corneal Ring Segments (Policy #058 in the Surgery Section)
  • Endothelial Keratoplasty (Policy #103 in the Surgery Section)

Policy:
(NOTE: For Medicare Advantage, please refer to the Medicare Coverage Section below for coverage guidance.)

1. The Boston (Dohlman-Doane) Keratoprosthesis (Boston KPro) is considered medically necessary for the surgical treatment of severe corneal opacification in situations where cadaveric corneal transplants have failed or have a very low likelihood of success (see Policy Guidelines).

2. All other types of permanent keratoprostheses are considered investigational.


Medicare Coverage:
There is no National Coverage Determination (NCD) for Keratoprosthesis. In the absence of an NCD, coverage decisions are left to the discretion of Local Medicare Carriers. Novitas Solutions, Inc, the Local Medicare Carrier for jurisdiction JL, has not issued a determination for this service. Therefore, Medicare Advantage Products will follow the Horizon BCBSNJ Medical Policy.


Policy Guidelines: (Information to guide medical necessity determination based on the criteria contained within the policy statements above.)

Implantation of a keratoprosthesis is considered a high-risk procedure associated with numerous complications and probable need for additional surgery. Therefore, the likelihood of regaining vision and the patient’s visual acuity in the contralateral eye should be taken into account when considering the appropriateness of this procedure. Treatment should be restricted to centers experienced in treating this condition and staffed by surgeons adequately trained in techniques addressing implantation of this device.
    • Conditions under which cadaveric corneal transplants have a likelihood of failure include but are not limited to the following:
    • The cornea is severely opaque and vascularized AND
    • Best-corrected visual acuity is 20/400 or less in the affected eye and 20/40 or less in the contralateral eye AND
    • No end-stage glaucoma or retinal detachment is present AND
    • The patient has one of the following indications:
        • History of 1 or more corneal transplant graft failures
        • Stevens-Johnson syndrome
        • Ocular cicatricial pemphigoid
        • Autoimmune conditions with rare ocular involvement
        • Ocular chemical burns
        • An ocular condition unlikely to respond favorably to primary corneal transplant surgery (eg, libel stem cell compromise or postherpetic anesthesia).
Note that patients should be able and expected to comply with postoperative care.


[RATIONALE: This policy was created in 2010 and has been updated regularly with searches of the MEDLINE database. The most recent literature update was performed through January 9, 2019.

Evidence reviews assess the clinical evidence to determine whether the use of a technology improves the net health outcome. Broadly defined, health outcomes are length of life, quality of life, and ability to function - including benefits and harms. Every clinical condition has specific outcomes that are important to patients and to managing the course of that condition. Validated outcome measures are necessary to ascertain whether a condition improves or worsens; and whether the magnitude of that change is clinically significant. The net health outcome is a balance of benefits and harms.

To assess whether the evidence is sufficient to draw conclusions about the net health outcome of a technology, 2 domains are examined: the relevance and the quality and credibility. To be relevant, studies must represent one or more intended clinical use of the technology in the intended population and compare an effective and appropriate alternative at a comparable intensity. For some conditions, the alternative will be supportive care or surveillance. The quality and credibility of the evidence depend on study design and conduct, minimizing bias and confounding that can generate incorrect findings. The randomized controlled trial is preferred to assess efficacy; however, in some circumstances, nonrandomized studies may be adequate. Randomized controlled trials are rarely large enough or long enough to capture less common adverse events and long-term effects. Other types of studies can be used for these purposes and to assess generalizability to broader clinical populations and settings of clinical practice.

The keratoprosthesis is intended for the relatively small number of patients with severe corneal damage who have lost vision and for whom a corneal transplant is not expected to result in satisfactory outcomes. These criteria generally refer to the population of patients who have failed one or more corneal transplants and who therefore have very few options to prevent blindness. Because this surgery is considered a salvage procedure with no acceptable alternative treatments, comparative studies are limited and/or lacking. The available literature primarily consists of retrospective case series. This policy examines the types of devices currently being tested in humans, focusing on reports that permit assessment of integration within the eye, durability, visual outcomes, and adverse events following implantation.

Boston (Dohlman-Doane) Keratoprosthesis (KPro)

Systematic Reviews

A 2015 systematic review from the American Academy of Ophthalmology identified 22 studies on the efficacy and safety of the Boston (Dohlman-Doane) Keratoprosthesis (Boston KPro).1, Studies were published in English and retrospective series had to include at least 25 eyes. The 22 studies included a total of 2176 eyes; sample sizes in individual studies ranged from 30 to 300 eyes. The proportion of patients with visual acuity of 20/200 after surgery ranged from 54% to 84% in the 10 studies reporting this outcome. Five articles reported that 11% to 39% of treated eyes attained visual acuities of 20/40 or better. Reviewers noted that published data were skewed toward visual improvement. Fourteen articles reported retention rates (eyes retaining the KPro device without loss, extrusion or dehiscence of the device), and these rates ranged from 65% to 100% (mean, 88%). The most common reasons for KPro loss were corneal melts with device exposure or extrusion, endophthalmitis, infectious keratitis, or corneal ulceration. The most common complication was retroprosthetic membrane formation, which ranged from 1% to 65% (mean, 30%) in the 13 studies reporting complications.

A systematic review by Ahmad et al (2016) examined 26 studies on repeat penetrating keratoplasty (PK) vs Boston KPro implantation after failed PK.2, Studies selected focused on patients with corneal opacity who had failed one or more PKs. Studies were excluded if they only selected patients with ocular surface disease. The primary outcome of interest was the proportion of patients with visual acuity of 20/200 or better at 2 or more years postsurgery. In a meta-analysis of 9 studies, the likelihood of 20/200 vision or better at least 2 years after repeat PK surgery was 42% (95% confidence interval [CI], 30% to 56%). A total of 104 eyes from 98 patients underwent KPro after failed PK surgery; 31 patients had only 1 previous PK. In a meta-analysis of data on KPro implantation after failed PK surgery, the probability of maintaining visual acuity of 20/200 or better at 2 years was 80% (95% CI, 68% to 88%). Among patients with a history of one failed PK, the probability of maintaining a visual acuity of 20/200 or better at 2 years was 74% (95% CI, 45% to 89%). (Reviewers did not specify the number of patients receiving KPro who were included in the analysis of 20/200 vision at 2 years.) In terms of complications after KPro following failed PK, at 2 years 29% of patients had elevated intraocular pressure and 8% needed surgery for glaucoma. In an analysis limited to patients undergoing KPro after 1 failed PK, complication rates ranging from 29% to 10% (which did not differ significantly from patients with KPro after >1 failed PKs). Reviewers did not report the number of patients included in the complication analyses.

Case Series

Representative larger series include a report from the Boston Type 1 Keratoprosthesis Study Group (2013) that assessed retention of the KPro device in 300 eyes of 300 patients.3, At a mean follow-up of 17.1 months (range, 1 week to 6 years), 93% of the keratoprostheses were retained. The probability of retention was 94% at 1 year and 89% at 2 years. Mean device durability was 3.8 years. Risk factors for keratoprosthesis loss were an autoimmune disease, ocular surface exposure, and a number of prior failed PK procedures. Additional data on this cohort were published in 2016.4, Preoperative visual acuities, available for 47% of eyes, was 20/1205. During a mean follow-up of 17 months (range, 1 week to 6 years), visual acuity improved significantly for 85% of eyes to a final mean of 20/150. Median time to achieve visual acuity of 20/200 was 1 month, and this level of acuity lasted for a mean of 48 months among patients with sufficient follow-up.

Srikumaran et al (2014) reported on a mean follow-up of 46.7 months (range, 6 weeks to 8.7 years) for 139 eyes of 133 patients who had received a Boston KPro at 1 of 5 tertiary referral centers in the United States.5 Twenty-seven percent of eyes underwent a primary KPro procedure while 73% had a prior donor graft failure. Postoperatively, visual acuity improved to at least 20/200 in 70% of eyes. The probability of maintaining visual acuity of at least 20/200 was 50%, and device retention was estimated at 67% at 7 years. The 7-year cumulative incidence of complications was 49.7% for retroprosthetic membrane formation, 21.6% for glaucoma surgery, 18.6% for retinal detachment, and 15.5% for endophthalmitis.

A prospective series of 265 eyes (265 patients) from 18 medical centers, published by the Boston Type 1 Keratoprosthesis Study Group (2012), focused on the time to development of retroprosthetic membranes.5, Most eyes (85.4%) had undergone an average of 2.2 (range, 1-8) PKs before keratoprosthesis implantation. The remaining eyes (14.6%) were considered at high-risk for PK failure and had received a primary keratoprosthesis. At a mean follow-up of 17.8 months, retroprosthetic membranes had formed in 31.7% of eyes. The mean time to development of retroprosthetic membranes was 216.7 days (range, 7 days to 4 years). Risk factors were the indication for the keratoprosthesis. Specifically, infectious keratitis had a hazard ratio of 3.2 (95% CI, 1.7 to 6.2) and aniridia had a hazard ratio of 3.1 (95% CI, 1.1 to 8.9).

Dunlap et al (2010) retrospectively analyzed 122 patients (126 eyes) at 2 centers who received a Boston type 1 KPro between 2004 and 2007.6, For most patients, the affected eye had a visual acuity of less than 20/400, and the contralateral eye did not have better vision. Of the 126 eyes, 112 had a history of multiple failed corneal grafts, and 14 had received the keratoprosthesis as a primary procedure due to the presence of limbal stem cell deficiency or significant ocular surface diseases. Following implantation, 96 (76%) eyes had improved vision, 22 (17.4%) eyes did not improve, and 8 (6.3%) eyes lost vision. At 3-month follow-up, 54% of eyes had 20/200 vision or better, with 18% achieving 20/40 or better. In approximately 45% of the eyes, visual acuity remained less than 20/400. The percentage of patients with improved visual outcomes was lower than in other published studies, due in part to the presence of comorbid conditions (eg, glaucoma, retinal detachment).

Adverse Events

Odorcic et al (2015) published a literature review on fungal infections after Boston type 1 KPro.7, They identified 15 relevant publications, primarily retrospective case series. Annual rates of fungal infections reported in these studies ranged from 0.9 to 2 per 100 patients. The largest case series assessed 291 eyes, and the cumulative incidence of fungal endophthalmitis was 2.4% over 10 years.

Chan et al (2016) retrospectively reviewed 110 patients (128 eyes) who received a Boston type 1 KPro, focusing on corneal melts, leaks, and extrusions.8, Mean follow-up was 29 months (range, 3-77 months). Melt-related complications requiring surgical repair occurred in 16% (20/128) of eyes; seven of these eyes had multiple episodes. The average time to a melt complication was 13 months after KPro implantation. Risk factors significantly associated with melt-related complications were previous infectious keratitis, and conjunctival deficiency caused by Stevens-Johnson syndrome, mucous membrane pemphigoid, or previous chemical injury.

Posterior segment complications were reported by Goldman et al (2013).9, Of 83 eyes (93 procedures) with follow-up of at least 6 months (range, 6-84 months), 38 (40.9%) eyes had at least 1 postoperative posterior segment complication, which included retinal detachment (16.9%), choroidal detachment (16.9%), and sterile vitritis (14.5%). Visual acuity was worse in eyes that experienced posterior segment complications than in eyes that did not.

Section Summary: Boston Keratoprosthesis

Numerous case series and systematic reviews of these series have assessed thousands of eyes implanted with the Boston KPro device. A 2015 systematic review of KPro efficacy included 22 series with a total of 2176 eyes. Studies with longer follow-up (ie, at least 2 years) have shown improved visual outcomes in a substantial percentage of patients with Boston KPro. This procedure is high-risk and is associated with numerous complications (eg, the growth of retroprosthetic membranes) and a probable need for additional surgery, thus careful patient selection is important.

AlphaCor Device

Studies have suggested that, with the AlphaCor device, thinning or “melting” of the anterior corneal surface can lead to loss of biointegration.10,11, This complication appears most prevalent in patients with ocular herpes, hence, the AlphaCor device is contraindicated in these patients.

Several case series have evaluated the AlphaCor. One of the larger was published by Hicks et al (2003).10, It included 40 devices implanted in 38 patients. At an average 30-month follow-up, 42% of eyes had visual acuity better than 20/200. Hoffart et al (2015) evaluated the AlphaCor device implanted in 12 patients.12, At a mean follow-up of 25 months, 8 (67%) of devices were retained, and patients had a mean gain in best-corrected visual acuity of 2.5 lines. The most common complication was corneal necrosis, observed in 7 (59%) patients, two of whom had a history of ocular herpes.

Section Summary: AlphaCor Device

Only a few published case series have evaluated the AlphaCor device, and hence there are insufficient data on improvements in vision outcomes this device. Moreover, the device has been associated with complications, including thinning or melting of the anterior corneal surface and corneal necrosis.

Osteo-Odonto-Keratoprosthesis

A systematic review by Tan et al (2012) included 8 case series describing surgical outcomes and complication rates of the osteo-odonto-keratoprosthesis (OOKP).13, Sample sizes ranged from 4 to 181 eyes. None of the studies was conducted in the United States. At 5 years, the pooled anatomic survival rate was 88% (range, 67%-100%) and, at 20 years, based on pooled data from 3 series, the anatomic survival rate was 81% (range, 65%-98%). About half of the patients obtained visual acuity better than 6/18. Visual acuity in the other patients was not described.

One of the largest case series (included in the Tan systematic review) is that by Falcinelli et al (2005), who reported on OOKP in 181 patients.14, At a median follow-up of 12 years, survival analysis estimated that the probability of retaining an anatomically intact OOKP 18 years after surgery with reasonable visual acuity was 85%.

In 2008, investigators from Spain retrospectively reviewed 227 patients who underwent OOKP (n=145) or osteokeratoprosthesis (OKP; n=82) using tibial bone in patients who lacked canine teeth to assemble the prosthesis.15, A second publication in 2011 from the same study examined the impact of clinical factors on long-term functional and anatomic outcomes.16, The primary diagnosis was chemical or thermal burn (48%), Steven-Johnson syndrome and Lyell syndrome (13%), cicatricial pemphigoid (11%), trachoma (11%), and other or not assignable (17%). Mean preoperative decimal best-corrected visual acuity was 0.00062 (range, light perception to 0.10). (On the decimal visual acuity scale, 0 = no light perception, 0.00001 = light perception, 0.0001 = light projection, and 0.001 = counting fingers.) Functional survival was defined as best-corrected visual acuity of 0.05 or more, and anatomic survival as retention of the keratoprosthesis lamina. Mean follow-up was 8.4 years for OOKP and 3.5 years for OKP. Anatomic success at 10 years was estimated to be 66% for OOKP and 47% for OKP. Functional success at 10 years was estimated to be 38% for OOKP and 17% for OKP. The best functional survival was in the Stevens-Johnson group, followed by chemical burn and trachoma. The least favorable prognosis was thermal burn. Complications included extrusion of the keratoprosthesis (28%), retinal detachment (16%), uncontrolled glaucoma (11%), infection (9%), retroprosthetic membrane (5%), and vitreous hemorrhage (3%). In cases without complications, functional survival was 57% at 5 years and 42% at 10 years.

Hughes et al (2008) reported on vitreoretinal complications of the OOKP in a retrospective review of 35 patients performed at 1 hospital in England between 1996 and 2005.17, Diagnoses were Stevens-Johnson syndrome in 15 patients, chemical injury in 5, mucous membrane pemphigoid in 3, and topical medication toxicity in 3. Follow-up at a mean 57 months (range, 13-105 months) revealed 9 vitreoretinal complications in 8 (23%) patients, which included vitreous hemorrhage, retinal detachment, and intraoperative choroidal hemorrhage. A 2008 report on 36 patients treated at the same hospital between 1996 and 2006 (likely to have reported patients assessed by Hughes17,) estimated that the probability of retaining visual acuity was 53% at 5 years and 44% at 9 years.18, In addition to the vitreoretinal complications causing loss of vision, resorption of the bony lamina led to visual or anatomic compromise in 7 (19%) cases.

Section Summary: Osteo-Odonto-Keratoprosthesis

A 2012 systematic review identified 8 case series evaluating OOKP, all of which were conducted outside of the United States, and no subsequent studies were identified. Pooled analyses of case series data found high anatomic survival rates at 5 and 20 years. However, vision outcomes were not well-described. The systematic review reported that half of the patients obtained visual acuity better than 6/18. OOKP is a complex surgical procedure and has been associated with a number of complications, including extrusion of the keratoprosthesis, retinal detachment, and vitreoretinal complications.

Summary of Evidence

For individuals who have corneal blindness and have failed or are not candidates for corneal transplantation who receive a Boston Keratoprosthesis (Boston KPro), the evidence includes case series and systematic reviews. Relevant outcomes are change in disease status, morbid events, quality of life, and treatment-related morbidity. Numerous case series have been published. Together, studies have assessed thousands of eyes. A 2015 systematic review of Boston KPro efficacy included 22 series with a total of 2176 eyes. Systematic reviews and case series with longer follow-up (ie, at least 2 years) have shown improvement in visual outcomes in a substantial percentage of patients with Boston KPro. This procedure is high-risk and associated with numerous complications (eg, the growth of retro prosthetic membranes) and a probable need for additional surgery, thus careful patient selection is important. The evidence is sufficient to determine that the technology results in a meaningful improvement in the net health outcome.

For individuals who have corneal blindness and have failed or are not candidates for corneal transplantation who receive a keratoprosthesis using the AlphaCor device, the evidence includes case series. Relevant outcomes are change in disease status, morbid events, quality of life, and treatment-related morbidity. Only a few published case series have evaluated the AlphaCor device. There are insufficient data on improvement in vision outcomes using the AlphaCor device. Moreover, the device has been associated with complications, including thinning or melting of the anterior corneal surface and corneal necrosis. The evidence is insufficient to determine the effects of the technology on health outcomes.

For individuals who have corneal blindness and have failed, or are not candidates for corneal transplantation who receive an osteo-odonto-keratoprosthesis, the evidence includes case series and a systematic review. Relevant outcomes are change in disease status, morbid events, quality of life, and treatment-related morbidity. A 2012 systematic review of case series, all conducted outside of the United States, found high anatomic survival rates at 5 and 20 years, but vision outcomes were not well-described. Osteo-odonto-keratoprosthesis is a complex surgical procedure and has been associated with a number of complications, including extrusion of the keratoprosthesis, retinal detachment, and vitreoretinal complications. The evidence is insufficient to determine the effects of the technology on health outcomes.

SUPPLEMENTAL INFORMATION

Clinical Input From Physician Specialty Societies and Academic Medical Centers

While the various physician specialty societies and academic medical centers may collaborate with and make recommendations during this process, through the provision of appropriate reviewers, input received does not represent an endorsement or position statement by the physician specialty societies or academic medical centers, unless otherwise noted.

In response to requests, input was received from 1 specialty society and 4 academic medical centers while this policy was under review in 2009. Reviewers generally supported a limited role for the Boston Keratoprosthesis in select patients. Some reviewers recommended use without first attempting a transplant under specific conditions that have a poor prognosis for corneal transplant; however, others found this controversial. Some reviewers recommended use only in patients with limited visual acuity in the contralateral eye. Overall, input indicated that the Boston Keratoprosthesis should be reserved for cases in which no other alternative (ie, corneal transplantation) is available for treatment of corneal opacification.

Practice Guidelines and Position Statements

A 2013 Preferred Practice Parameter on ocular edema and opacification by the American Academy of Ophthalmology did not provide specific recommendations on the keratoprosthesis, but included this discussion of the technology19,:

“…Significant improvements in the design and postoperative management of the Boston type 1 keratoprosthesis has resulted in a steady rise in the number of these procedures performed both in the United States and abroad. Reduced incidence of postoperative stromal necrosis and bacterial endophthalmitis due to the chronic use of protective soft contact lenses and topical antibiotics has resulted in improved retention and visual outcomes and has had a positive impact on surgeons’ perceptions of when to recommend keratoprosthesis. Once considered a procedure of last resort in patients with severe bilateral visual impairment, it is now being used for a variety of unilateral and bilateral indications, such as ocular trauma, herpetic keratitis, aniridia, Stevens-Johnson syndrome, and congenital corneal opacification. More recently, as corneal surgeons have gained a greater appreciation of the failure rate of repeat corneal transplantation, a role for a keratoprosthetic in cases of multiple graft failure has become clearer.”

“Patients with severe dry eye and autoimmune ocular surface diseases (particularly Stevens-Johnson syndrome and OMMP [ocular mucous membrane pemphigoid]) remain a difficult management group despite the other successes of the Boston type 1 keratoprosthetic. Epithelial defects, scleral necrosis, extrusion, and endophthalmitis are the principal concerns. This group of patients has had some success with a Boston type 2 keratoprosthetic designed to be used through the lid and the osteo-odonto-keratoprosthesis.”

U.S. Preventive Services Task Force Recommendations

Not applicable.

Ongoing and Unpublished Clinical Trials

Some currently unpublished trials that might influence this review are listed in Table 1.

Table 1. Summary of Key Trials
NCT No.Trial NamePlanned EnrollmentCompletion Date
Ongoing
NCT02084745Timing of Glaucoma Drainage Device With Boston KPro Surgery (GDD-KPro)
40
Mar 2020

NCT: national clinical trial.]
________________________________________________________________________________________

Horizon BCBSNJ Medical Policy Development Process:

This Horizon BCBSNJ Medical Policy (the “Medical Policy”) has been developed by Horizon BCBSNJ’s Medical Policy Committee (the “Committee”) consistent with generally accepted standards of medical practice, and reflects Horizon BCBSNJ’s view of the subject health care services, supplies or procedures, and in what circumstances they are deemed to be medically necessary or experimental/ investigational in nature. This Medical Policy also considers whether and to what degree the subject health care services, supplies or procedures are clinically appropriate, in terms of type, frequency, extent, site and duration and if they are considered effective for the illnesses, injuries or diseases discussed. Where relevant, this Medical Policy considers whether the subject health care services, supplies or procedures are being requested primarily for the convenience of the covered person or the health care provider. It may also consider whether the services, supplies or procedures are more costly than an alternative service or sequence of services, supplies or procedures that are at least as likely to produce equivalent therapeutic or diagnostic results as to the diagnosis or treatment of the relevant illness, injury or disease. In reaching its conclusion regarding what it considers to be the generally accepted standards of medical practice, the Committee reviews and considers the following: all credible scientific evidence published in peer-reviewed medical literature generally recognized by the relevant medical community, physician and health care provider specialty society recommendations, the views of physicians and health care providers practicing in relevant clinical areas (including, but not limited to, the prevailing opinion within the appropriate specialty) and any other relevant factor as determined by applicable State and Federal laws and regulations.

___________________________________________________________________________________________________________________________

Index:
Keratoprosthesis
AlphaCor Keratoprosthesis
Boston Keratoprosthesis (KPro)
Chirila keratoprosthesis (Chirila KPro)
Dohlman Doane Keratoprosthesis
Boston KPro

References:
1. Lee WB, Shtein RM, Kaufman SC, et al. Boston Keratoprosthesis: outcomes and complications: a report by the American Academy of Ophthalmology. Ophthalmology. Jul 2015;122(7):1504-1511. PMID 25934510

2. Ahmad S, Mathews PM, Lindsley K, et al. Boston Type 1 Keratoprosthesis versus repeat donor keratoplasty for corneal graft failure: a systematic review and meta-analysis. Ophthalmology. Jan 2016;123(1):165-177. PMID 26545318

3. Ciolino JB, Belin MW, Todani A, et al. Retention of the Boston keratoprosthesis type 1: multicenter study results. Ophthalmology. Jun 2013;120(6):1195-1200. PMID 23499061

4. Rudnisky CJ, Belin MW, Guo R, et al. Visual acuity outcomes of the Boston Keratoprosthesis Type 1: multicenter study results. Am J Ophthalmol. Feb 2016;162:89-98 e81. PMID 26550696

5. Rudnisky CJ, Belin MW, Todani A, et al. Risk factors for the development of retroprosthetic membranes with Boston keratoprosthesis type 1: multicenter study results. Ophthalmology. May 2012;119(5):951-955. PMID 22361316

6. Dunlap K, Chak G, Aquavella JV, et al. Short-term visual outcomes of Boston type 1 keratoprosthesis implantation. Ophthalmology. Apr 2010;117(4):687-692. PMID 20096462

7. Odorcic S, Haas W, Gilmore MS, et al. Fungal infections after Boston Type 1 Keratoprosthesis Implantation: literature review and in vitro antifungal activity of hypochlorous acid. Cornea. Dec 2015;34(12):1599-1605. PMID 26488624

8. Chan CC, LoVerde L, Qiang J, et al. Incidence, risk factors, and surgical management of Boston Type 1 Keratoprosthesis corneal melts, leaks, and extrusions. Cornea. Aug 2016;35(8):1049-1056. PMID 27391092

9. Goldman DR, Hubschman JP, Aldave AJ, et al. Postoperative posterior segment complications in eyes treated with the Boston type I keratoprosthesis. Retina. Mar 2013;33(3):532-541. PMID 23073339

10. Hicks CR, Crawford GJ, Lou X, et al. Corneal replacement using a synthetic hydrogel cornea, AlphaCor: device, preliminary outcomes and complications. Eye (Lond). Apr 2003;17(3):385-392. PMID 12724702

11. Crawford GJ, Hicks CR, Lou X, et al. The Chirila Keratoprosthesis: phase I human clinical trial. Ophthalmology. May 2002;109(5):883-889. PMID 11986092

12. Hoffart L, Carles G, Matonti F. Lamellar corneal lenticule graft to treat keratolysis after AlphaCor keratoprosthesis implantation. Eur J Ophthalmol. Jan-Feb 2015;25(1):1-7. PMID 25198171

13. Tan A, Tan DT, Tan XW, et al. Osteo-odonto keratoprosthesis: systematic review of surgical outcomes and complication rates. Ocul Surf. Jan 2012;10(1):15-25. PMID 22330056

14. Falcinelli G, Falsini B, Taloni M, et al. Modified osteo-odonto-keratoprosthesis for treatment of corneal blindness: long-term anatomical and functional outcomes in 181 cases. Arch Ophthalmol. Oct 2005;123(10):1319-1329. PMID 16219722

15. Michael R, Charoenrook V, de la Paz MF, et al. Long-term functional and anatomical results of osteo- and osteoodonto-keratoprosthesis. Graefes Arch Clin Exp Ophthalmol. Aug 2008;246(8):1133-1137. PMID 18491123

16. De La Paz MF, De Toledo JA, Charoenrook V, et al. Impact of clinical factors on the long-term functional and anatomic outcomes of osteo-odonto-keratoprosthesis and tibial bone keratoprosthesis. Am J Ophthalmol. May 2011;151(5):829-839. PMID 21310387

17. Hughes EH, Mokete B, Ainsworth G, et al. Vitreoretinal complications of osteoodontokeratoprosthesis surgery. Retina. Oct 2008;28(8):1138-1145. PMID 18779721

18. Liu C, Okera S, Tandon R, et al. Visual rehabilitation in end-stage inflammatory ocular surface disease with the osteo-odonto-keratoprosthesis: results from the UK. Br J Ophthalmol. Sep 2008;92(9):1211-1217. PMID 18511541

19. American Academy of Ophthalmology Cornea/External Disease Panel. Prefered Practice Parameter: Corneal Edema and Opacification. San Francisco, CA: American Academy of Ophthalmology; 2013.


Codes:
(The list of codes is not intended to be all-inclusive and is included below for informational purposes only. Inclusion or exclusion of a procedure, diagnosis, drug or device code(s) does not constitute or imply authorization, certification, approval, offer of coverage or guarantee of payment.)

CPT*

    65770
HCPCS
    C1818
    L8609

* CPT only copyright 2020 American Medical Association. All rights reserved. CPT is a registered trademark of the American Medical Association.
_________________________________________________________________________________________

Medical policies can be highly technical and are designed for use by the Horizon BCBSNJ professional staff in making coverage determinations. Members referring to this policy should discuss it with their treating physician, and should refer to their specific benefit plan for the terms, conditions, limitations and exclusions of their coverage.

The Horizon BCBSNJ Medical Policy Manual is proprietary. It is to be used only as authorized by Horizon BCBSNJ and its affiliates. The contents of this Medical Policy are not to be copied, reproduced or circulated to other parties without the express written consent of Horizon BCBSNJ. The contents of this Medical Policy may be updated or changed without notice, unless otherwise required by law and/or regulation. However, benefit determinations are made in the context of medical policies existing at the time of the decision and are not subject to later revision as the result of a change in medical policy

____________________________________________________________________________________________________________________________