Subject:
Patient-Controlled End Range of Motion Stretching Devices
Description:
_______________________________________________________________________________________
IMPORTANT NOTE:
The purpose of this policy is to provide general information applicable to the administration of health benefits that Horizon Blue Cross Blue Shield of New Jersey and Horizon Healthcare of New Jersey, Inc. (collectively “Horizon BCBSNJ”) insures or administers. If the member’s contract benefits differ from the medical policy, the contract prevails. Although a service, supply or procedure may be medically necessary, it may be subject to limitations and/or exclusions under a member’s benefit plan. If a service, supply or procedure is not covered and the member proceeds to obtain the service, supply or procedure, the member may be responsible for the cost. Decisions regarding treatment and treatment plans are the responsibility of the physician. This policy is not intended to direct the course of clinical care a physician provides to a member, and it does not replace a physician’s independent professional clinical judgment or duty to exercise special knowledge and skill in the treatment of Horizon BCBSNJ members. Horizon BCBSNJ is not responsible for, does not provide, and does not hold itself out as a provider of medical care. The physician remains responsible for the quality and type of health care services provided to a Horizon BCBSNJ member.
Horizon BCBSNJ medical policies do not constitute medical advice, authorization, certification, approval, explanation of benefits, offer of coverage, contract or guarantee of payment.
__________________________________________________________________________________________________________________________
Patient-controlled stretching devices are used at home to increase range of motion (ROM) in patients who have impaired functional status due to decreased ROM. We address two types of commercially available devices. Static progressive stretch (SPS) devices (eg, JAS, Static-Pro) provide low- to moderate-intensity stretching with a crank or ratchet that progressively increases the stretch within each session, and serial stretch devices (eg, ERMI) use hydraulics to alternate between periods of higher intensity stretch and relaxation.
Populations | Interventions | Comparators | Outcomes |
Individuals:
· With functional limitations in range of motion | Interventions of interest are:
· Static progressive stretch devices and physical therapy | Comparators of interest are:
· Physical therapy alone
· Dynamic stretch device
· Surgical release | Relevant outcomes include:
· Symptoms
· Change in disease status
· Functional outcomes
· Quality of life |
Individuals:
· With functional limitations in range of motion | Interventions of interest are:
· Serial stretch devices and physical therapy | Comparators of interest are:
· Physical therapy alone
· Dynamic stretch device
· Surgical release | Relevant outcomes include:
· Symptoms
· Change in disease status
· Functional outcomes
· Quality of life |
Background
Range of Motion Impairments
Loss of full ROM occurs in a significant proportion of patients following surgical procedures around a joint, such as total knee arthroplasty or anterior cruciate ligament reconstruction. The most common cause of severe postoperative motion loss is the development of intra-articular or extra-articular arthrofibrosis. Arthrofibrosis, characterized by periarticular fibrosis and bands of scar tissue, is described as a painful loss of end ROM compared with the normal contralateral side. Loss of knee ROM can lead to impairments in walking, sitting, rising from a chair, and navigating stairs. Stephenson et al (2010) estimated that based on the annual rates of total knee arthroplasty and anterior cruciate ligament reconstruction, the number of major knee surgery patients affected by arthrofibrosis in the United States would be at least 85000 per year, and approximately 21000 patients each year would be at risk of requiring additional surgery.1,
Treatment
Treatment of arthrofibrosis may include physical therapy, manipulation under anesthesia, arthroscopic or open lysis of adhesions, or revision surgery. Conservative treatment typically consists of postoperative physical therapy with pressure stretching techniques and home exercises. When rehabilitation has failed, serial casting, static braces, or dynamic splints that provide low-load prolonged stretch may be used. Dynamic splints use spring loading or elastic bands to provide low-intensity tension (less than that exerted by a physical therapist) and are designed to be worn over relatively long periods (ie, 6-8 hours or overnight).
Static Progressive Stretch Devices
This policy focuses on patient-controlled mechanical devices that provide either moderate- to high-intensity stretch or static progressive stretch (SPS) in the home. The efficacy of a stretching regimen to permanently remodel tissue is considered to be a function of the intensity, length of the session, number of sessions per day, and number of days per week that stretching is performed.2 SPS devices provide a low- to moderate-intensity force to hold a joint at its end range and gradually increase the stretch. In contrast to the long periods of low-intensity stretch provided by dynamic splinting devices, patient-controlled serial stretch and SPS devices are designed to be used for 15 to 30 minutes, in up to 8 sessions per day.
SPS devices are available for the knee, shoulder, ankle, wrist, and for pronation and supination. Patients are typically instructed to use them for 30 minutes, 3 times a day. During each session, patients adjust their device by turning a ratchet or turnbuckle to the maximum tolerated position of end range stretch. Each position is held for several minutes to allow for tissue relaxation to occur, and the device is then advanced to a new position of stretch. It is proposed that the systems unload the joint to reduce joint surface pressures during the stretch. Devices that provide SPS include JAS® (Joint Active Systems), Static-Pro® (DeRoyal), Stat-A-Dyne® (Ortho-Innovations), AliMed® Turnbuckle Orthosis (AliMed), and Mayo Aircast® (DJO).
Serial Stretch Devices
Patient-controlled serial stretch devices in the home include the ERMI line. Specific ERMI devices are the Shoulder Flexionater, Knee Flexionater, Knee Extensionater, Elbow Extensionater, and the MPJ Extensionater. They are intended primarily to address excessive scar tissue around the joint by alternating progressive stretching with periods of relaxation, at a torque similar to that applied by physical therapists that is near or at the pain threshold. The patient uses a hydraulic pump to control the load, which can range from a few ounces to 227 kilograms (500 pounds). For example, to use the ERMI Knee/Ankle Flexionater, patients pull a lever to increase knee flexion angle, and the amount of torque being applied to the joint. The hydraulic system amplifies the force of the lever into a greater torque applied to the knee for five to tenminutes. Periods of flexion are interspersed by 5- to 10-minute recovery intervals where the knee is released back into extension.
Outcome Measures
Improvement in functional outcomes, such as the ability to perform activities of daily living is the primary goal of this intervention. Joint ROM is an intermediate outcome. One small study (2000) correlated knee ROM with functional parameters and concluded that 110° is considered the functional ROM necessary to allow patients to perform common activities of daily living such as navigating stairs, rising from a low chair or commode, entering or exiting from a car, or tying one’s shoes.2, This threshold of ROM is therefore used as a measure of treatment success for individual patients. Loss of knee ROM of more than 15°, which occurs in about 1% to 2% of patients after anterior cruciate ligament reconstruction, has been associated with loss of quadriceps muscle strength and the development of osteoarthritis.3,According to the knee examination form developed by the International Knee Documentation Committee (2000), an extension deficit of 6° to 10° or a flexion deficit of 16° to 25° when compared with the noninvolved knee is categorized “abnormal,” and an extension deficit of more than 10° or a flexion deficit of more than 25° when compared with the noninvolved knee is categorized “severely abnormal.”4, ROM thresholds in joints other than the knee have been less clearly defined.
Regulatory Status
The U.S. Food and Drug Administration has determined that devices classified as “Exerciser, Non-Measuring” are considered class I devices and exempt from 510(k) requirements. This classification does not require submission of clinical data on efficacy, only notification to the Food and Drug Administration prior to marketing. Food and Drug Administration product code: ION.
Related Policies
Policy:
(NOTE: For Medicare Advantage, Medicaid and FIDE-SNP, please refer to the Coverage Sections below for coverage guidance.)
Patient-controlled end range of motion stretching devices are considered investigational.
Medicare Coverage:
There is no National Coverage Determination (NCD) for patient-controlled end range of motion stretching devices. In the absence of an NCD, coverage decisions are left to the discretion of Local Medicare Carriers. Noridian Healthcare Services, LLC, the Local DME Medicare Carrier for jurisdiction JA, has not issued a determination for this service. Therefore, Medicare Advantage Products will follow the Horizon BCBSNJ Medical Policy.
Medicaid Coverage:
For members enrolled in Medicaid and NJ FamilyCare plans, Horizon BCBSNJ applies the above medical policy.
FIDE SNP:
For members enrolled in a Fully Integrated Dual Eligible Special Needs Plan (FIDE-SNP): (1) to the extent the service is covered under the Medicare portion of the member’s benefit package, the above Medicare Coverage statement applies; and (2) to the extent the service is not covered under the Medicare portion of the member’s benefit package, the above Medicaid Coverage statement applies.
[RATIONALE: This policy was created in 2015 and has been updated regularly with searches of the MEDLINE database. The most recent literature update was performed through January 9, 2019.
Evidence reviews assess the clinical evidence to determine whether the use of technology improves the net health outcome. Broadly defined, health outcomes are the length of life, quality of life (QOL), and ability to function - including benefits and harms. Every clinical condition has specific outcomes that are important to patients and managing the course of that condition. Validated outcome measures are necessary to ascertain whether a condition improves or worsens; and whether the magnitude of that change is clinically significant. The net health outcome is a balance of benefits and harms.
To assess whether the evidence is sufficient to draw conclusions about the net health outcome of technology, two domains are examined: the relevance, and quality and credibility. To be relevant, studies must represent one or more intended clinical use of the technology in the intended population and compare an effective and appropriate alternative at a comparable intensity. For some conditions, the alternative will be supportive care or surveillance. The quality and credibility of the evidence depend on study design and conduct, minimizing bias and confounding that can generate incorrect findings. The randomized controlled trial (RCT) is preferred to assess efficacy; however, in some circumstances, nonrandomized studies may be adequate. RCTs are rarely large enough or long enough to capture less common adverse events and long-term effects. Other types of studies can be used for these purposes and to assess generalizability to broader clinical populations and settings of clinical practice. The following is a summary of the key literature to date.
Static Progressive Stretch Devices
Several case series on JAS devices have been published by a group of investigators that include Bonutti (stockholder in Joint Active Systems), McGrath, Ulrich, and Mont. Also, three RCTs, one evaluating JAS devices in the knee, shoulder, and elbow, and a systematic review of case reports and case series were identified. Characteristics and outcomes for the three RCTs are reported in Tables 1 and 2.
Knee
Randomized Controlled Trials
Papotto and Mills (2012) reported on a small (n=20) RCT that compared high-intensity serial stretch with lower intensity static progressive stretch (SPS) devices for home therapy in patients who had undergone total knee arthroplasty.5, High-intensity stretch was performed with the ERMI Knee/Ankle Flexionater. Patients in this high-intensity stretch group were instructed to stretch at an intensity that mimicked the intensity provided by their physical therapists during outpatient sessions and to use the device in 20- to 30-minute sessions, for a total of 60 minutes per day. The lower intensity stretch group used an SPS device (Static-Pro Knee), which consists of a brace secured to the upper and lower leg with cuffs and straps. These patients were instructed to use the Static-Pro Knee in 3, 30-minute sessions each day, increasing the force applied to the joint every 5 minutes. After an average of seven weeks of treatment, patients treated with ERMI reported significantly greater improvement in knee flexion, range of motion (ROM), and Western Ontario and McMaster University Osteoarthritis Index (WOMAC) scores compared with the SPS patients (see Table 1).
Case Series
Bonutti et al (2008) reported on a series of 41 patients with refractory knee stiffness who used an SPS (JAS) device after failing physical therapy.6, Patients in this study had a total ROM of less than 90° or a flexion contracture that impaired QOL. Twenty-five patients had previously undergone manipulation under anesthesia. After a mean of 9 weeks of use (range, 3-27 weeks), mean ROM increased by 33° (range, 0°-85°), with mean final extension of -6° and flexion of 108°. Outcomes were comparable to those reported with other nonoperative treatments;however, improvements occurred in shorter treatment times with the SPS device.
Shoulder
Randomized Controlled Trials
Ibrahim et al (2012) published an evaluator-blinded RCT of 60 patients with shoulder adhesive capsulitis randomized to 4 weeks of treatment with an SPS (JAS) device plus physical therapy compared with physical therapy alone.7, The trial was independently funded, although devices were provided by Joint Active Systems. Patients were evaluated for ROM, functional outcomes with the Disabilities of the Arm Shoulder and Hand (DASH) questionnaire, and a visual analog scale for pain. Improvements in ROM and DASH scores were significantly greater with the SPS device than with physical therapy alone (see Table 1). Over 24 weeks of follow-up, these improvements were maintained in the JAS group but declined in the group treated with physical therapy alone. Ibrahim et al (2014) and Hussein et al (2015) provided additional follow-up at 1 year and 2 years.8,9, At 1- and 2-year follow-ups, ROM was substantially greater in the SPS group (p<0.001), due primarily to an increase in DASH scores (higher scores indicate a decrease in ROM) for the group treated with physical therapy over two years. The difference between groups in ROM at 2 years was 47.6° for passive external rotation, 29.1° for passive abductions, and 75.3° for active abduction. Final DASH scores were 2.5 in the SPS group compared with 36.2 in the control group (p<0.001). Visual analog scale scores for pain were low in both the SPS (1.2) and control (1.7; p=0.05) groups. Because there was no reporting of losses to follow-up over two years or references to the prior publications, results of this study might have been biased. It is also unclear why functional limitations would increase in the control group when adhesive capsulitis is generally a self-limiting condition.
Elbow
Randomized Controlled Trials
Lindenhovius et al (2012) reported on results from an RCT that compared SPS using a JAS device with dynamic splinting in 66 patients with posttraumatic elbow stiffness.10, Patients included had lost more than 30° in flexion or extension after an elbow injury or surgery and had failed to improve for at least 4 weeks with regular stretching exercises. The evaluation was conducted by an investigator not involved in the care of the patients but who did not appear to have been blinded. Ten percent of patients in the dynamic splinting cohort asked for a change in treatment due to discomfort with the splint. Follow-up at 12 months was available for 80% of patients in the SPS group and 68% of patients in the splinting group, potentially reflecting lower patient satisfaction with dynamic splinting. Improvements were comparable between the groups in most outcomes (flexion-extension arc, flexion, forearm rotation), with the exception of DASH scores (significantly better in the SPS group at 6 months but equivalent at 12 months) and flexion contracture (equivalent at 6 months but significantly better in the splinting group at 12 months), (see Table 1). Statistical analysis was intention-to-treat but did not account for repeated measures or baseline covariates. ROM was similar between groups at all time points.
Case Series
Ulrich et al (2010) reported on the use of an SPS (JAS) elbow device in 37 patients. Patients with deficits in flexion or extension had undergone at least six weeks of exercise with at least two weeks of minimal motion gain (<5°).11, After 1 to 3 daily, 30-minute sessions for a mean treatment time of 10 weeks (range, 2-23 weeks), mean ROM increased by 26° (range, 2°-60°) to a final ROM of 107° (range, 70°-140°). Results were compared with the literature on other upper-extremity stretch devices (eg, splints), which achieved similar success rates (81%-88%) with 6 to 10 hours of daily wear over 6 to 10 months.
Systematic Reviews
A systematic review by Muller et al (2013) compared the effectiveness of dynamic splint, static splint, or SPS in patients with posttraumatic or postoperative elbow stiffness.12, They included 13 case series and case reports (totaln=247 patients; range, 1-37 patients). Mean time from the incident to the start of treatment was 6.9 months. The greatest increase in ROM was obtained with dynamic splints (46°), followed by SPS devices (40°) and static splints (34°). These differences were statistically significant (p<0.001) but might not be clinically significant. None of the selected studies assessed patient compliance, which is potentially affected by the duration of wear and comfort of the device. This systematic review was limited by the inclusion of low-quality studies, including case reports.
Forearm Rotation
Case Series
McGrath et al (2009) reported on a series of 38 consecutive patients with limitations in forearm rotation who had plateaued with physical therapy.13, Treatment with an SPS (JAS) pronation/supination device began at an average of 21 weeks (range, 6-75 weeks) after the upper-extremity injury. At the start of treatment, mean ROM was 96° (range, 20°-150°). After an average of 12 weeks of treatment (range, 3-57 weeks), mean ROM increased to 138° (range, 70°-180°).
Wrist
Case Series
McGrath et al (2008) also reported on the use of an SPS (JAS) wrist device in 47 consecutive patients with posttraumatic or postsurgical wrist stiffness.14, All patients’ ROM had plateaued (67°; range, 18°-114°) after a mean of 12 weeks of physical therapy (range, 6-28 weeks) and was not expected to improve with standard therapeutic modalities. After a mean of 10 weeks of SPS treatment (range, 4-26 weeks), ROM increased to 101° (range, 60°-156°).
Lucado et al (2008) retrospectively reviewed 25 patients with distal radius fractures who had been treated with a JAS Flexion/Extension device or JAS forearm Pronation/Supination device at their institutions.15, Mean time from injury to the initiation of treatment with an SPS device was 94 days (range, 48-188 days), and duration of use was 75 days (range, 14-160 days). There were significant improvements in ROM and DASH scores. Median DASH score improved from 43 to 19 (/100) after SPS therapy.
Table 1. Summary Characteristics of RCTs Using SPS Devices to Treat Restricted ROM
Author | Countries | Sites | Dates | Participants | Interventions |
 |  |  |  |  | Active | Comparator |
Serial stretch (ERMI Flexionater/Extensionater) device vs SPS device |  |
Papotto and Mills (2012)5, | U.S. | 1 | NR | 20 patients >65 y with arthrofibrosis after TKA | HIS (Knee Flexionater) for 5-10 min followed by 5-10 min recovery for 20-30 min a session, totaling 60 min/d | LIS (Static-Pro Knee); increase in force every 5 min for 30 min, 3 times/day |
SPS device vs PT |  |  |  |  |
Ibrahim et al (2012)7, | U.S. | NR | NR | 60 patients with shoulder adhesive capsulitis | PT plus SPS: one 30-min session/day (week 1), two 30-min sessions/day (weeks 2-3), three 30-min sessions/day (week 4) | PT |
SPS device vs dynamic splint |  |  |  |  |
Lindenhovius et al (2012)10, | U.S. | 1 | 2003-2008 | 66 patients with posttraumatic elbow stiffness | SPS device (Joint Active Systems), for three 30-min sessions/day, to improvement plateau | Dynamic splints, 6-8 h/d continuously, to improvement plateau |
HIS: high-intensity stretch; LIS: low-intensity stretch; NR: not reported; PT: physical therapy; RCT: randomized controlled trial; SPS: static progressive stretch; TKA: total knee arthroplasty.
Table 2. Summary Results of RCTs Using SPS Devices to Treat Restricted ROM
 | After 7 Weeks of Treatment | After 4 Weeks of Treatment | Mean at 6-Month Follow-Up |
Study | Knee Flexion >110° | Change in ROM | Change in WOMAC Scores | Change in Active Abduction | Change in Passive Abduction | Change in External Rotation | Change in DASH Scores | Flexion Arc (Range) | Change in DASH Scores (Range) |
Papotto and Mills (2012)5, |  |  |  |  |  |  |  |  |
HIS | 91% | 29.9° | 25.6 |  |  |  |  |  |  |
LIS | 22% | 17.0° | 12.4 |  |  |  |  |  |  |
p | <0.001 | 0.001 | 0.048 |  |  |  |  |  |  |
Ibrahim et al (2012)7, |  |  |  |  |  |  |  |  |
SPS |  |  |  | 76° | 64° | 53° | 68 |  |  |
PT |  |  |  | 46° | 37° | 30° | 58 |  |  |
p |  |  |  | <0.001 | <0.001 | <0.001 | <0.001 |  |  |
Lindenhovius et al (2012)10, |  |  |  |  |  |  |  |  |
SPS |  |  |  |  |  |  |  | 91° (50°-140°) | 25 (3-50) |
DS |  |  |  |  |  |  |  | 93° (15°-130°) | 32 (5-83) |
p |  |  |  |  |  |  |  | 0.80 | <0.05 |
DASH: Disabilities of the Arm Shoulder and Hand questionnaire; HIS: high-intensity stretch; LIS: low-intensity stretch; PT: physical therapy; RCT: randomized controlled trial; ROM: range of motion; SPS: static progressive stretch; WOMAC: Western Ontario and McMaster University Osteoarthritis Index.
Section Summary: SPS Devices
The evidence on SPS devices is limited and conflicting. One RCT found greater improvements in ROM and WOMAC scores with serial stretch devices for the knee compared with SPS devices. Another RCT evaluating SPS for shoulder adhesive capsulitis found significant differences in DASH scores and shoulder ROM compared with physical therapy alone at the end of four weeks of treatment, with the differences maintained after two years. A third RCT found comparable improvements in most outcomes for the SPS device compared with dynamic splinting, except better DASH scores in the SPS group at 6 months and better flexion contracture in the dynamic splinting group at 12 months. A systematic review of case reports and series found similar clinical efficacy for increasing elbow ROM between SPS devices and dynamic splints. It is not known whether patient compliance was higher with the SPS devices because results have indicated these devices improve ROM faster than other modalities.
Serial Stretch Devices
Knee
Randomized Controlled Trials
The small RCT by Papotto and Mills ([2012] described above) compared a serial stretch (ERMI Knee/Ankle Flexionater) device with an SPS (Static-Pro) device for home therapy in 20 patients who had undergone total knee arthroplasty.5, After an average of 7 weeks of therapy, treatment with the serial stretch device resulted in a 29.9° gain in motion compared with 17.0° with SPS (p<0.001). Knee flexion of 110° or more was obtained in 91% of the serial stretch group compared with 22% of the SPS group (p<0.001). Improvement on the 100-point WOMAC was significantly greater in the serial stretch group (25.6) than in the SPS group (12.4; p=0.048) (see Table 1).
Nonrandomized Comparative Studies
Stephenson et al (2010) reported on an industry-funded retrospective comparative study of high-intensity stretch devices, low-intensity stretch devices, and no devices, based on claims data for 60359 patients who had a diagnosis of arthrofibrosis following knee injury or surgery.1,There were 143 patients who used a high-intensity stretch device, 607 who used a low-intensity stretch device, and 59609 who did not use any stretching device. To make the groups comparable in terms of severity, the lower intensity stretch and no device patients were required to have a diagnosis relating to osteoarthrosis, ankyloses, contracture/fracture, or stiffness in the lower leg. After controlling for baseline differences in the type of knee surgery and musculoskeletal disease, the high-intensity stretch group had significantly lower rates of rehospitalization than low-intensity stretch and no device patients. Significantly more patients with no device (47.4%) had a knee event within 6 months from the index surgery compared with high-intensity (24.5%) or low-intensity (22.2%) stretch patients.
Uncontrolled Trials
A frequently cited study was reported by Branch et al (2003; Branch was medical director at ERMI).16, Patients (n=34) in this prospective series who did not have full knee ROM after 6 weeks of physical therapy were prescribed a serial stretch (ERMI Knee/Ankle Flexionater) device. The 2 patients in the study who had ROM greater than 115° at the start of therapy regained full ROM. Of the 6 patients with ROM between 90° and 115° at the start of therapy, 5 gained full ROM; and of the 16 patients with ROM between 60° and 90° at the start of therapy, 13 regained full ROM. For the 10 patients who began mechanical therapy with ROM between 0° and 60°, only 4 regained full ROM but this group regained the most ROM (mean, 79°) of the 4 groups. With functional ROM defined as 115° or more, 31 (91%) of the 34 patients met this goal, and the improvement in ROM for the entire group was highly significant. A retrospective review from this group found that passive knee extension deficits that had plateaued with physical therapy decreased from 10.5° to
2.0° with the ERMI Knee Extensionater.
Shoulder
Case Series
An industry-funded retrospective series (2011) with 36 patients was identified; it evaluated a serial stretch (ERMI Shoulder Flexionater) device.17, Patients with adhesive capsulitis who had failed six weeks of physical therapy (glenohumeral abduction and external rotation not equal to the opposite uninvolved limb) were treated with the serial stretch device in combination with continued physical therapy. Patients were instructed to perform six daily, ten-minute sessions of end range stretching at home, using an intensity that was uncomfortable but not painful. Blinded evaluation at the end of treatment found that ROM of the involved limb equaled that of the opposite limb. Scores on the American Shoulder and Elbow Society Standardized Shoulder Assessment Form showed significant improvement (p<0.05), and patients with greater pain at baseline had the greatest improvement in American Shoulder and Elbow Society scores (gain of 50 points of 100 total).
Section Summary: Serial Stretch Devices
The evidence includes a small RCT and a larger retrospective comparative study that reported high-intensity stretching using serial stretch (ERMI) devices improved ROM more than lower intensity stretching devices in patients who were post injury or surgery. Other available data consist of retrospective case series demonstrating improvements in ROM among patients whose ROM had plateaued with physical therapy. The clinical significance of gains in this surrogate outcome measure is unclear.
Summary of Evidence
For individuals who have functional limitations in ROM who receive SPS devices and physical therapy, the evidence includes RCTs, a systematic review, and case series. The relevant outcomes include symptoms, change in disease status, functional outcomes, and QOL. Three RCTs have evaluated SPS devices but comparators in each differed (physical therapy, a dynamic splint, and a serial stretch device). One RCT reported significant improvements in Disabilities of the Arm Shoulder and Hand questionnaire scores and shoulder ROM compared with physical therapy alone at the end of four 4 weeks of treatment, with significant improvements maintained at the two-year follow-up. A second RCT evaluating SPS in the elbow found similar improvements in most ROM outcomes compared with dynamic splinting, except better Disabilities of the Arm Shoulder and Hand scores in the SPS group at 6 months and better flexion contracture in the dynamic splinting group at 12 months. A third RCT, which compared SPS with serial stretch devices, found greater improvements in WOMAC and knee flexion scores with the serial stretch devices. A systematic review and meta-analysis of case reports and series found that similar clinical efficacy for increasing elbow ROM and flexion can be achieved using dynamic splints, SPS devices, and static braces. It is not known whether patient compliance is higher with SPS devices because results have indicated these devices improve ROM faster than comparators. The evidence is insufficient to determine the effects of the technology on health outcomes.
For individuals who have functional limitations in ROM who receive serial stretch devices and physical therapy, the evidence includes an RCT and observational studies. The relevant outcomes include symptoms, change in disease status, functional outcomes, and QOL. The best evidence consists of serial stretching with ERMI devices used to treat knee ROM. One small RCT and a larger retrospective comparative study have reported that high-intensity stretching with ERMI devices improved ROM more than lower intensity stretching devices in patients who were post injury or surgery. Other available data consist of retrospective case series that have demonstrated improved ROM in patients whose ROM had plateaued with physical therapy. The clinical significance of gains in this surrogate outcome measure is unclear. Further high-quality comparative trials are needed to determine whether these patient-controlled devices improve functional outcomes better than alternative treatments and identify the patient populations that might benefit. The evidence is insufficient to determine the effects of the technology on health outcomes.
SUPPLEMENTAL INFORMATION
Practice Guidelines and Position Statements
No guidelines or statements were identified.
U.S. Preventive Services Task Force Recommendations
Not applicable.
Ongoing and Unpublished Clinical Trials
Currently unpublished trials that might influence this review are listed in Table 3.
Table 3. Summary of Key Trials
NCT No. | Trial Name | Planned Enrollment | Completion Date |
Unpublished |  |  |  |
NCT01618227 | A Prospective Randomized Trial of Rehabilitation With or Without Static Progressive Splinting for Wrist Stiffness | 60 | Jan 2015
(completed) |
NCT: national clinical trial.
________________________________________________________________________________________
Horizon BCBSNJ Medical Policy Development Process:
This Horizon BCBSNJ Medical Policy (the “Medical Policy”) has been developed by Horizon BCBSNJ’s Medical Policy Committee (the “Committee”) consistent with generally accepted standards of medical practice, and reflects Horizon BCBSNJ’s view of the subject health care services, supplies or procedures, and in what circumstances they are deemed to be medically necessary or experimental/ investigational in nature. This Medical Policy also considers whether and to what degree the subject health care services, supplies or procedures are clinically appropriate, in terms of type, frequency, extent, site and duration and if they are considered effective for the illnesses, injuries or diseases discussed. Where relevant, this Medical Policy considers whether the subject health care services, supplies or procedures are being requested primarily for the convenience of the covered person or the health care provider. It may also consider whether the services, supplies or procedures are more costly than an alternative service or sequence of services, supplies or procedures that are at least as likely to produce equivalent therapeutic or diagnostic results as to the diagnosis or treatment of the relevant illness, injury or disease. In reaching its conclusion regarding what it considers to be the generally accepted standards of medical practice, the Committee reviews and considers the following: all credible scientific evidence published in peer-reviewed medical literature generally recognized by the relevant medical community, physician and health care provider specialty society recommendations, the views of physicians and health care providers practicing in relevant clinical areas (including, but not limited to, the prevailing opinion within the appropriate specialty) and any other relevant factor as determined by applicable State and Federal laws and regulations.
___________________________________________________________________________________________________________________________
Index:
Patient-Controlled End Range of Motion Stretching Devices
Patient Controlled End Range of Motion Stretching Devices
Patient-Actuated End Range of Motion Stretching Devices
Patient Actuated End Range of Motion Stretching Devices
Joint Active Systems
JAS
JAS Elbow
JAS Shoulder, JAS Ankle
JAS Knee
JAS Wrist
JAS Pronation-Supination.
End Range of Motion Improvement
ERMI
Flexionater
Shoulder Flexionater
Knee Flexionater
Extensionater
Knee Extensionate
Elbow Extensionater
MPJ Extensionater
Static-Pro
Static Pro
Static-Pro Knee
Static-Pro Wrist
Static-Pro Elbow
Elite Seat
References:
1. Stephenson JJ, Quimbo RA, Gu T. Knee-attributable medical costs and risk of re-surgery among patients utilizing non-surgical treatment options for knee arthrofibrosis in a managed care population. Curr Med Res Opin. May 2010;26(5):1109-1118. PMID 20225995.
2. Rowe PJ, Myles CM, Walker C, et al. Knee joint kinematics in gait and other functional activities measured using flexible electrogoniometry: how much knee motion is sufficient for normal daily life? Gait Posture. Oct 2000;12(2):143-155. PMID 10998612.
3. Shelbourne KD, Gray T. Minimum 10-year results after anterior cruciate ligament reconstruction: how the loss of normal knee motion compounds other factors related to the development of osteoarthritis after surgery. Am J Sports Med. Mar 2009;37(3):471-480. PMID 19059893.
4. International Knee Documentation Committee (IKDC). IKDC: Knee Form. 2000; http://www.aaos.org/uploadedFiles/PreProduction/Quality/Measures/IKDCEnglishUS.pdf. Accessed February 8, 2018.
5. Papotto BA, Mills T. Treatment of severe flexion deficits following total knee arthroplasty: a randomized clinical trial. Orthop Nurs. Jan-Feb 2012;31(1):29-34. PMID 22278649.
6. Bonutti PM, McGrath MS, Ulrich SD, et al. Static progressive stretch for the treatment of knee stiffness. Knee. Aug 2008;15(4):272-276. PMID 18538574.
7. Ibrahim MI, Johnson AJ, Pivec R, et al. Treatment of adhesive capsulitis of the shoulder with a static progressive stretch device: a prospective, randomized study. J Long Term Eff Med Implants. Jan 2012;22(4):281-291. PMID 23662659.
8. Ibrahim M, Donatelli R, Hellman M, et al. Efficacy of a static progressive stretch device as an adjunct to physical therapy in treating adhesive capsulitis of the shoulder: a prospective, randomised study. Physiotherapy. Sep 2014;100(3):228-234. PMID 24211154.
9. Hussein AZ, Ibrahim MI, Hellman MA, et al. Static progressive stretch is effective in treating shoulder adhesive capsulitis: Prospective, randomized, controlled study with a two-year follow-up. Eur J Physiother. Jun 24 2015;17(3):138-147.
10. Lindenhovius AL, Doornberg JN, Brouwer KM, et al. A prospective randomized controlled trial of dynamic versus static progressive elbow splinting for posttraumatic elbow stiffness. J Bone Joint Surg Am. Apr 18 2012;94(8):694-700. PMID 22517385.
11. Ulrich SD, Bonutti PM, Seyler TM, et al. Restoring range of motion via stress relaxation and static progressive stretch in posttraumatic elbow contractures. J Shoulder Elbow Surg. Mar 2010;19(2):196-201. PMID 19959379.
12. Muller AM, Sadoghi P, Lucas R, et al. Effectiveness of bracing in the treatment of nonosseous restriction of elbow mobility: a systematic review and meta-analysis of 13 studies. J Shoulder Elbow Surg. Aug 2013;22(8):1146-1152. PMID 23796383.
13. McGrath MS, Ulrich SD, Bonutti PM, et al. Static progressive splinting for restoration of rotational motion of the forearm. J Hand Ther. Jan-Mar 2009;22(1):3-8; quiz 9. PMID 18950990.
14. McGrath MS, Ulrich SD, Bonutti PM, et al. Evaluation of static progressive stretch for the treatment of wrist stiffness. J Hand Surg Am. Nov 2008;33(9):1498-1504. PMID 18984330.
15. Lucado AM, Li Z, Russell GB, et al. Changes in impairment and function after static progressive splinting for stiffness after distal radius fracture. J Hand Ther. Oct-Dec 2008;21(4):319-325. PMID 19006757.
16. Branch TP, Karsch RE, Mills TJ, et al. Mechanical therapy for loss of knee flexion. Am J Orthop (Belle Mead NJ). Apr 2003;32(4):195-200. PMID 12723771.
17. Dempsey AL, Mills T, Karsch RM, et al. Maximizing total end range time is safe and effective for the conservative treatment of frozen shoulder patients. Am J Phys Med Rehabil. Sep 2011;90(9):738-745. PMID 21430510.
Codes:
(The list of codes is not intended to be all-inclusive and is included below for informational purposes only. Inclusion or exclusion of a procedure, diagnosis, drug or device code(s) does not constitute or imply authorization, certification, approval, offer of coverage or guarantee of payment.)
CPT*
HCPCS
E1801
E1806
E1811
E1816
E1818
E1831
E1841
* CPT only copyright 2020 American Medical Association. All rights reserved. CPT is a registered trademark of the American Medical Association.
_________________________________________________________________________________________
Medical policies can be highly technical and are designed for use by the Horizon BCBSNJ professional staff in making coverage determinations. Members referring to this policy should discuss it with their treating physician, and should refer to their specific benefit plan for the terms, conditions, limitations and exclusions of their coverage.
The Horizon BCBSNJ Medical Policy Manual is proprietary. It is to be used only as authorized by Horizon BCBSNJ and its affiliates. The contents of this Medical Policy are not to be copied, reproduced or circulated to other parties without the express written consent of Horizon BCBSNJ. The contents of this Medical Policy may be updated or changed without notice, unless otherwise required by law and/or regulation. However, benefit determinations are made in the context of medical policies existing at the time of the decision and are not subject to later revision as the result of a change in medical policy
____________________________________________________________________________________________________________________________ |