Horizon BCBSNJ
Uniform Medical Policy ManualSection:D M E
Policy Number:002
Effective Date: 01/04/2018
Original Policy Date:02/25/1993
Last Review Date:08/13/2019
Date Published to Web: 10/04/2017
Subject:
Oscillatory Devices for the Treatment of Cystic Fibrosis and Other Respiratory Disorders

Description:
_______________________________________________________________________________________

IMPORTANT NOTE:

The purpose of this policy is to provide general information applicable to the administration of health benefits that Horizon Blue Cross Blue Shield of New Jersey and Horizon Healthcare of New Jersey, Inc. (collectively “Horizon BCBSNJ”) insures or administers. If the member’s contract benefits differ from the medical policy, the contract prevails. Although a service, supply or procedure may be medically necessary, it may be subject to limitations and/or exclusions under a member’s benefit plan. If a service, supply or procedure is not covered and the member proceeds to obtain the service, supply or procedure, the member may be responsible for the cost. Decisions regarding treatment and treatment plans are the responsibility of the physician. This policy is not intended to direct the course of clinical care a physician provides to a member, and it does not replace a physician’s independent professional clinical judgment or duty to exercise special knowledge and skill in the treatment of Horizon BCBSNJ members. Horizon BCBSNJ is not responsible for, does not provide, and does not hold itself out as a provider of medical care. The physician remains responsible for the quality and type of health care services provided to a Horizon BCBSNJ member.

Horizon BCBSNJ medical policies do not constitute medical advice, authorization, certification, approval, explanation of benefits, offer of coverage, contract or guarantee of payment.

__________________________________________________________________________________________________________________________

Oscillatory devices are alternatives to the standard daily percussion and postural drainage method of airway clearance for patients with cystic fibrosis. There are several types of devices including high-frequency chest compression with an inflatable vest and oscillating positive expiratory pressure devices, such as the Flutter and Acapella devices. Respiratory therapies and other providers may also use oscillatory devices are also proposed for other respiratory conditions such as diffuse bronchiectasis, chronic obstructive pulmonary disease, and respiratory conditions associated with neuromuscular disorders.

PopulationsInterventionsComparatorsOutcomes
Individuals:
    • With cystic fibrosis
Interventions of interest are:
    • Oscillatory devices
Comparators of interest are:
    • Standard chest physical therapy
Relevant outcomes include:
    • Symptoms
    • Quality of life
    • Hospitalizations
    • Medication use
Individuals:
    • With bronchiectasis
Interventions of interest are:
    • Oscillatory devices
Comparators of interest are:
    • Standard chest physical therapy
Relevant outcomes include:
    • Symptoms
    • Quality of life
    • Hospitalizations
    • Medication use
Individuals:
    • With chronic obstructive pulmonary disease
Interventions of interest are:
    • Oscillatory devices
Comparators of interest are:
    • Standard therapy
Relevant outcomes include:
    • Symptoms
    • Quality of life
    • Hospitalizations
    • Medication use
Individuals:
    • With respiratory conditions related to neuromuscular disorders
Interventions of interest are:
    • Oscillatory devices
Comparators of interest are:
    • Standard therapy
Relevant outcomes include:
    • Symptoms
    • Quality of life
    • Hospitalizations
    • Medication use

BACKGROUND

Oscillatory devices are designed to move mucus and clear airways; the oscillatory component can be intra- or extrathoracic. Some devices require the active participation of patients. They include oscillating positive expiratory pressure devices, such as Flutter and Acapella, in which the patient exhales multiple times through a device. The Flutter device is a small pipe-shaped, easily portable handheld device, with a mouthpiece at one end. It contains a high-density, stainless steel ball that rests in a plastic circular cone. During exhalation, the steel ball moves up and down, creating oscillations in expiratory pressure and airflow. When the oscillation frequency approximates the resonance frequency of the pulmonary system, the vibration of the airways occurs, resulting in loosening of mucus. The Acapella device is similar in concept but uses a counterweighted plug and magnet to create air flow oscillation.

Other airway clearance techniques also require active patient participation. For example, autogenic drainage and an active cycle breathing technique both involve a combination of breathing exercises performed by the patient. Positive expiratory pressure therapy requires patients to exhale through a resistor to produce positive expiratory pressures during a prolonged period of exhalation. It is hypothesized that the positive pressure supports the small airway such that the expiratory airflow can better mobilize secretions.

High-frequency chest wall oscillation devices (eg, the Vest Airway Clearance System, ThAIRapy Bronchial Drainage System, SmartVest Airway Clearance System) are passive oscillatory devices designed to provide airway clearance without the active patient participation. The Vest Airway Clearance System provides high-frequency chest compression using an inflatable vest and an air-pulse generator. Large-bore tubing connects the vest to the air-pulse generator. The air-pulse generator creates pressure pulses that inflate and deflate the vest against the thorax, creating high-frequency chest wall oscillation and mobilization of pulmonary secretions.

The Percussionaire device is another type of passive oscillatory device; it delivers intrapulmonary percussive ventilation. This device combines internal thoracic percussion through rapid minibursts of inhaled air and continuous therapeutic aerosol delivered through a nebulizer.

All of these techniques may be alternatives to daily percussion and postural drainage in patients with cystic fibrosis, also known as check physical therapy. Daily percussion and postural drainage need to be administered by a physical therapist or another trained adult in the home, often a parent if the patient is a child. The necessity for regular therapy can be particularly burdensome for adolescents or adults who lead independent lifestyles. Oscillatory devices can also potentially be used by patients with other respiratory disorders to promote bronchial secretion drainage and clearance, such as diffuse bronchiectasis and chronic obstructive pulmonary disease. Additionally, they could benefit patients with neuromuscular disease who have impaired cough clearance.

This policy addresses the outpatient use of oscillatory devices. We do not address inpatient device use (eg, in the immediate postsurgical period) here.

Regulatory Status

Several oscillatory devices have been cleared for marketing by the U.S. Food and Drug Administration through the 510(k) process, including those listed in Table 1.

Table 1. Select Oscillatory Devices Cleared by the Food and Drug Administration
DeviceManufacturerClearance Date
Flutter® Mucus Clearance DeviceAxcan Scandipharm (for marketing in the United States)1994
Vestä Airway Clearance SystemHill-Rom1998
Acapella® deviceDHD Healthcare1999
RC Cornetä Mucus Clearing DevicePARI Respiratory Equipment1999
inCourage® SystemRespirTech2005
AerobiKA oscillating PEP deviceTrudell Medical2013
Vibralung Acoustical PercussorWestmed2014
The vest airway clearance systemHill-Rom2015
The Monarch™ Airway Clearance SystemHill-Rom2017
PEP: positive expiratory pressure.

Food and Drug Administration product codes: BYI, BYT.

Related Policies

  • None

Policy:
(NOTE: For Medicare Advantage, Medicaid and FIDE-SNP, please refer to the Coverage Sections below for coverage guidance.)

1. Use of an oscillatory positive expiratory pressure (PEP) device (e.g., Flutter® valve, Acapella device) is considered medically necessary for members with hypersecretory lung disease (i.e., produce excessive mucus) who have difficulty clearing the secretions and recurrent disease exacerbations.

2. High-frequency chest wall compression devices and intrapulmonary percussive ventilation devices are considered medically necessary in members with cystic fibrosis or chronic diffuse bronchiectasis (see definition below in the Policy Guidelines section) when standard chest physiotherapy has failed OR standard chest physiotherapy is unavailable or not tolerated.
    In considering the chest wall compression and intrapulmonary percussion ventilation devices, there should be demonstrated need for airway clearance. There should also be documented failure of standard treatments (i.e., the member has frequent severe exacerbations of respiratory distress involving inability to clear mucus despite standard treatment [chest physiotherapy and, if appropriate, use of an oscillatory positive expiratory pressure device] or valid reasons why standard treatment cannot be performed, such as inability of the caregiver to perform it).
3. High-frequency chest wall compression devices are considered medically necessary in members with neuromuscular disorders when standard treatments including mechanical insufflation-exsufflation and standard chest physiotherapy have failed to adequately mobilize retained secretion (e.g., prior history of pneumonia or worsening of pulmonary condition), or standard chest physiotherapy is unavailable or not tolerated. Examples of neuromuscular disorders include the following:
    • Post-polio
    • Acid maltase deficiency
    • Anterior horn cell disease
    • Multiple sclerosis
    • Quadriplegia
    • Hereditary muscular dystrophy
    • Myotonic disorders
    • Other myopathies
    • Paralysis of the diaphragm

4. An acoustical percussor, positive airway pressure (PEP), and aerosol drug delivery system combination device (e.g., Vibralung) is considered medically necessary when both of the following criteria are met:
    • the member meets the medical necessity criteria for a high-frequency chest wall compression device; AND
    • the member is unable to use a high-frequency chest wall compression device (i.e., burns, chest trauma).

5. Other applications of high-frequency chest wall compression devices and intrapulmonary percussive ventilation devices, including, but not limited to, their use in members with cystic fibrosis, chronic diffuse bronchiectasis, or respiratory conditions associated with neuromuscular disorders other than as specified in policy statements 2 and 3 above, their use as an adjunct to chest physiotherapy, and their use in other lung diseases, such as chronic obstructive pulmonary disease, are considered investigational.


Medicare Coverage:
There are multiple NCDs and LCDs applicable to Oscillatory Devices for the Treatment of Cystic Fibrosis and Other Respiratory Disorders. For eligibility and coverage information, please refer to the following:

National Coverage Determination (NCD) for Intrapulmonary Percussive Ventilator (IPV) (240.5). Available to be accessed at CMS National Coverage Determinations (NCDs) Alphabetical Index search page: https://www.cms.gov/medicare-coverage-database/indexes/ncd-alphabetical-index.aspx.

Local Coverage Determination (LCD): High Frequency Chest Wall Oscillation Devices (L33785). Available to be accessed at Noridian Healthcare Services, LLC, (DME MAC), Local Coverage Determinations (LCDs) search page: https://www.cms.gov/medicare-coverage-database/indexes/lcd-list.aspx?Cntrctr=389&ContrVer=1&CntrctrSelected=389*1&s=38&DocType=All&bc=AggAAAAAAAAAAA%3d%3d&#ResultsAnchor.

Local Coverage Determination (LCD): Intrapulmonary Percussive Ventilation System (L33786). Available to be accessed at Noridian Healthcare Services, LLC, (DME MAC), Local Coverage Determinations (LCDs) search page: https://www.cms.gov/medicare-coverage-database/indexes/lcd-list.aspx?Cntrctr=389&ContrVer=1&CntrctrSelected=389*1&s=38&DocType=All&bc=AggAAAAAAAAAAA%3d%3d&#ResultsAnchor.

Local Coverage Article: Intrapulmonary Percussive Ventilation System - Policy Article (A52495). Available to be accessed at Noridian Healthcare Services, LLC, (DME MAC), Local Coverage Determinations (LCDs) search page: https://www.cms.gov/medicare-coverage-database/indexes/lcd-list.aspx?Cntrctr=389&ContrVer=1&CntrctrSelected=389*1&s=38&DocType=All&bc=AggAAAAAAAAAAA%3d%3d&#ResultsAnchor.

Local Coverage Article: High Frequency Chest Wall Oscillation Devices - Policy Article (A52494). Available to be accessed at Noridian Healthcare Services, LLC, (DME MAC), Local Coverage Determinations (LCDs) search page: https://www.cms.gov/medicare-coverage-database/indexes/lcd-list.aspx?Cntrctr=389&ContrVer=1&CntrctrSelected=389*1&s=38&DocType=All&bc=AggAAAAAAAAAAA%3d%3d&#ResultsAnchor.


Medicaid Coverage:

For members enrolled in Medicaid and NJ FamilyCare plans, Horizon BCBSNJ applies the above medical policy.

FIDE SNP:

For members enrolled in a Fully Integrated Dual Eligible Special Needs Plan (FIDE-SNP): (1) to the extent the service is covered under the Medicare portion of the member’s benefit package, the above Medicare Coverage statement applies; and (2) to the extent the service is not covered under the Medicare portion of the member’s benefit package, the above Medicaid Coverage statement applies.

Policy Guidelines: (Information to guide medical necessity determination based on the criteria contained within the policy statements above.)

For this policy, chronic diffuse bronchiectasis is defined by daily productive cough for at least 6 continuous months or exacerbations more than 2 times per year requiring antibiotic therapy and confirmed by high-resolution or spiral chest computed tomography scan.

For the chest wall compression devices, a trial period to determine patient and family compliance may be considered. Those who appear to benefit most from the compression devices are adolescents and adults due to lifestyle factors in which manual percussion and postural drainage may not be available.

A trial period may also be helpful because patients’ responses to different types of devices can vary; the types of devices should be considered as alternative, not equivalent, devices.

[RATIONALE: This policy was created in 1993 and has been updated regularly with searches of the MEDLINE database. The most recent literature update was performed through April 1, 2019.

Evidence reviews assess the clinical evidence to determine whether the use of a technology improves the net health outcome. Broadly defined, health outcomes are length of life, quality of life, and ability to function-including benefits and harms. Every clinical condition has specific outcomes that are important to patients and to managing the course of that condition. Validated outcome measures are necessary to ascertain whether a condition improves or worsens; and whether the magnitude of that change is clinically significant. The net health outcome is a balance of benefits and harms.

To assess whether the evidence is sufficient to draw conclusions about the net health outcome of a technology, 2 domains are examined: the relevance and the quality and credibility. To be relevant, studies must represent one or more intended clinical use of the technology in the intended population and compare an effective and appropriate alternative at a comparable intensity. For some conditions, the alternative will be supportive care or surveillance. The quality and credibility of the evidence depend on study design and conduct, minimizing bias and confounding that can generate incorrect findings. The randomized controlled trial (RCT) is preferred to assess efficacy; however, in some circumstances, nonrandomized studies may be adequate. RCTs are rarely large enough or long enough to capture less common adverse events and long-term effects. Other types of studies can be used for these purposes and to assess generalizability to broader clinical populations and settings of clinical practice.

Cystic Fibrosis

Clinical Context and Therapy Purpose

The purpose of oscillatory positive expiratory pressure (PEP) therapy in patients who have cystic fibrosis (CF) is to provide a treatment option that is an alternative to or an improvement on existing therapies.

The question addressed in this policy is: Does use of oscillatory devices improve health outcomes in patients with CF?

The following PICOTS were used to select literature to inform this review.

Patients

The relevant population of interest is individuals with cystic fibrosis.

Interventions

The therapy being considered is the application of oscillatory PEP.

Comparators

The following therapy is currently being used: standard chest physical therapy.

Outcomes

The general outcomes of interest are reductions in respiratory symptoms due to airway restrictions caused by a mucous buildup in the lungs.

Timing

Changes in outcomes over a minimum 3-month period should be considered meaningful.

Setting

Oscillatory PEP devices are intended to be used primarily in home setting by patients themselves.

Systematic Reviews

A number of RCTs and a Cochrane systematic review of RCTs have evaluated oscillatory devices for treating patients with CF. The Cochrane review addressed a variety of oscillatory devices and was last updated by Morrison and Agnew (2014)1, and is summarized in Table 2. Outcomes included pulmonary function, sputum weight and volume, hospitalization rate, and quality of life (QOL) measures. The overall risk of bias was unclear in about 85% of studies. Data could not be pooled due to the variety of devices, outcome measures, and lengths of follow-up used. Reviewers concluded that there was a lack of evidence supporting the superiority of oscillatory devices vs any other form of physical therapy or that 1 device was superior over another and that there is a need for adequately powered RCTs with long-term follow-up.

Table 2. Characteristics of Systematic Reviews
StudyDatesTrialsParticipantsN (Range)DesignDuration
Morrison et al (2014)1,1995-2014
35a
Patients with cystic fibrosis1050 (5-166)RCT and controlled studies1 wk to 1 y
Ten were published only as abstracts, 16 were conducted in the United States, and 14 were single-center studies.

Representative recent RCTs follow. Trial characteristics and results are summarized in Tables 3 and 4. Gaps related to relevance, study design, and conduct are summarized in Tables 5 and 6.

Mcllwaine et al (2013) published an RCT comparing high-frequency chest wall oscillation (HFCWO) with PEP mask therapy.2,The primary outcome measure was the number of pulmonary exacerbations requiring an antibiotic. At the end of 1 year, patients in the PEP arm had a statistically significant lower incidence of pulmonary exacerbations requiring antibiotics compared with HFCWO group. The time to first pulmonary exacerbation was 220 days in the PEP group and 115 days in the HFCWO group (p=0.02). There were no statistically significant differences in pulmonary measures, including the forced expiratory volume in 1 second (FEV1).

Sontag et al (2010) published a multicenter RCT that compared postural drainage, the Flutter device, and HFCWO.3 At study termination, patients had a final assessment; the length of participation ranged from 1.3 to 2.8 years. An intention-to-treat analysis found no significant differences between treatment groups in the modeled rate of decline for percent predicted FEV1 or forced vital capacity (FVC). The small sample size and high dropout rate limited the conclusions drawn from this trial.

Pryor et al (2010) evaluated 75 patients ages 16 years and older with CF from a single center in the U.K.3, Sixty-five (87%) of 75 patients completed the trial and were included in the analysis. Although the study was described as a noninferiority trial, it was not statistically analyzed as such. Instead, no statistically significant differences among the regimens in the primary outcome measure of FEV1were construed as evidence for noninferiority.

Radtke et al (2018) evaluated 15 adult patients with cystic fibrosis using the Flutter with moderate intensity interval cycling exercise to measure pulmonary diffusing capacity. The outcomes of interest included pulmonary function, sputum viscosity and volume, hospitalization rate and QOL measures. The results yielded no differences in absolute changes in pulmonary diffusion capacity. This study is not represented in the study tables within this review.

Table 3. Summary of Key RCT Characteristics
StudyCountriesSitesDatesParticipantsInterventions
ActiveComparator
Mcllwaine et al (2013)2,Canada122008 -2012Children with CF age >6 y (n=107)HFCWO (n=56)PEP mask therapy (n=51)
Sontag et al (2010)4,U.S.201999-2002Adults and children with CF (n=166)2 active Tx: flutter (n=58) and vest (n=57)Postural drainage (n=58)
Pryor et al (2010)3,U.K.1NRPatients with CF ≥16 y (n=75)Cornet (n=15), Flutter (n=15), PEP (n=15), autogenic drainage (n=15)Active cycle of breathing technique (n=15)
CF: cystic fibrosis; HFCWO: high- frequency chest wall oscillation; NR: not reported; PEP: positive expiratory pressure; RCT: randomized controlled trial; Tx: treatment.

Table 4. Summary of Key RCT Outcomes
StudyNo. of PEs Requiring AntibioticsSpirometryQuality of Life
Mcllwaine et al (2013)2,88Cannot confirmNot applicable
HFCWOData not reportedOutcome not evaluated
N96
Median2.00
Range1.00-3.00
Positive expiratory pressureData not reportedOutcome not evaluated
N49
Median1.00
Range0.00-2.00
p0.007No differenceNot applicable
Sontag et al (2010)4,
FulterOutcome not evaluatedData not reportedOutcome not evaluated
VestOutcome not evaluatedData not reportedOutcome not evaluated
Postural drainageOutcome not evaluatedData not reportedOutcome not evaluated
pNo difference
Pryor et al (2010)3,Not applicable
65
Not applicable
Active cycle of breathing techniquesOutcome not evaluatedFEV1 at 0 mo: 2.01

FEV1 at 12 mo: 1.94

Small improvement (0.7)a
Autogenic drainageOutcome not evaluatedFEV1 at 0 mo: 2.68
FEV
1 at 12 mo: 2.64
Small improvement (0.5)a
CornetOutcome not evaluatedFEV1 at 0 mo: 1.93

FEV1 at 12 mo: 1.90

No difference (<0.5)a
FlutterOutcome not evaluatedFEV1 at 0 mo: 2.46

FEV1 at 12 mo: 2.43

Moderate improvement (1.3)a
Positive expiratory pressureOutcome not evaluatedFEV1 at 0 mo: 2.17
FEV
1 at 12 mo: 2.02
Small improvement (0.8)a
pNot applicableNo differenceNot reported
FEV1: forced expiratory volume in 1 second; HFCWO: high-frequency chest wall oscillation; PE: pulmonary exacerbations; RCT: randomized controlled trial.

a Minimal important differences in the Chronic Respiratory Questionnaire. A change of 0.5 represents a small difference in symptoms, 1.0 a moderate difference, and 1.5 a large difference

Table 5. Relevance Gaps
StudyPopulationaInterventionbComparatorcOutcomesdFollow-Upe
Mcllwaine et al (2013)2,
Sontag et al (2010)4,
Pryor et al (2010)3,
The evidence gaps stated in this table are those notable in the current review; this is not a comprehensive gaps assessment.
Population key: 1. Intended use population unclear; 2. Clinical context is unclear; 3. Study population is unclear; 4. Study population not representative of intended use.

bIntervention key: 1. Not clearly defined; 2. Version used unclear; 3. Delivery not similar intensity as comparator; 4.Not the intervention of interest.

c Comparator key: 1. Not clearly defined; 2. Not standard or optimal; 3. Delivery not similar intensity as intervention; 4. Not delivered effectively.

d Outcomes key: 1. Key health outcomes not addressed; 2. Physiologic measures, not validated surrogates; 3. No CONSORT reporting of harms; 4. Not establish and validated measurements; 5. Clinical significant difference not prespecified; 6. Clinical significant difference not supported.

e Follow-Up key: 1. Not sufficient duration for benefit; 2. Not sufficient duration for harms.

Table 6. Study Design and Conduct Gaps
StudyAllocationaBlindingbSelective
Reportingd
Follow-UpePowerdStatisticalf
Mcllwaine et al (2013)2,3. Allocation concealment unclear1.Not blinded to treatment assignment1. Eighty-eight (82%) of 107 randomized patients completed the trial. Trial limitations were a nearly 20% dropout rate.4. Trial stopped early without enrolling expected number of patients and might have been underpowered to detect clinically significant differences between groups
Sontag et al (2010)4,3. Allocation concealment unclear1.Not blinded to treatment assignment1. Dropout rates were high;trial ended early: 35 (60%), 16 (31%), and 5 (9%) patients withdrew from the postural drainage, Flutter, and Vest groups, respectively. Most common reasons for withdrawal after 60 days were moved or lost to follow-up (n=13) and lack of time (n=7).4. Trial ended earlier than planned
Pryor et al (2010)3,3. Allocation concealment unclear1. Not blinded to treatment assignment1. Ten of 75 randomized patients were lost to follow-up
The evidence gaps stated in this table are those notable in the current review; this is not a comprehensive gaps assessment.

FEV1: forced expiratory volume in 1 second.
Allocation key: 1. Participants not randomly allocated; 2. Allocation not concealed; 3. Allocation concealment unclear; 4. Inadequate control for selection bias.

bBlinding key: 1. Not blinded to treatment assignment; 2. Not blinded outcome assessment; 3. Outcome assessed by treating physician.

c Selective Reporting key: 1. Not registered; 2. Evidence of selective reporting; 3. Evidence of selective publication.

d Follow-Up key: 1. High loss to follow-up or missing data; 2. Inadequate handling of missing data; 3. High number of crossovers; 4. Inadequate handling of crossovers; 5. Inappropriate exclusions; 6. Not intent to treat analysis (per protocol for noninferiority trials).

e Power key: 1. Power calculations not reported; 2. Power not calculated for primary outcome; 3. Power not based on clinically important difference; 4. Target sample size not achieved.

f Statistical key: 1. Intervention is not appropriate for outcome type: (a) continuous; (b) binary; (c) time to event; 2. Intervention is not appropriate for multiple observations per patient; 3. Confidence intervals and/or p values not reported; 4.Comparative treatment effects not calculated.

Section Summary: Cystic Fibrosis

A number of RCTs evaluating oscillatory devices have reported mixed findings and limitations (eg, small sample sizes, large dropout rates). A systematic review identified 35 RCTs comparing oscillatory devices with another recognized airway clearance techniques; some were published only as abstracts. The study findings were not pooled due to heterogeneity in designs and outcome measures. A systematic review concluded that results from additional RCTs with adequate power and long-term follow-up would permit conclusions on the effect of oscillatory devices on outcomes for CF.

Other Respiratory Disorders

Clinical Context and Therapy Purpose

The purpose of oscillatory PEP therapy in patients who have other respiratory disorders (eg, bronchiectasis, chronic obstructive pulmonary disease [COPD], respiratory conditions related to neuromuscular disorders) is to provide a treatment option that is an alternative to or an improvement on existing therapies.

The question addressed in this policy is: Does use of oscillatory devices improve health outcomes in patients with other respiratory disorders (eg, bronchiectasis, COPD, respiratory conditions related to neuromuscular disorders)?

The following PICOTS were used to select literature to inform this review.

Patients

The relevant population of interest is individuals with other respiratory disorders (eg, bronchiectasis, COPD, respiratory conditions related to neuromuscular disorders).

Interventions

The therapy being considered is the application of an oscillatory PEP.

Comparators

The following therapy is currently being used: standard chest physical therapy or standard therapy.

Outcomes

The general outcomes of interest are reductions in respiratory symptoms due to airway restrictions (eg, pulmonary exacerbations).

Timing

Changes in outcomes over a minimum 3-month period should be considered meaningful.

Setting

Oscillatory PEP devices are intended to be used primarily in home setting by patients themselves.

Bronchiectasis

Lee et al (2015) published a Cochrane review of airway clearance techniques for treating bronchiectasis, which is summarized in Table 7.5, Of 7 RCTs included, 6 were crossover trials. Five trials used a PEP device, one used HFCWO, and one used postural drainage. Reviewers did not pool study findings due to heterogeneity among studies. Primary outcomes of interest were pulmonary exacerbations, hospitalizations for bronchiectasis, and QOL.

Table 7. Characteristics of Systematic Reviews
StudyDatesTrialsParticipantsN (Range)DesignDuration
Lee et al (2015)5,1966-20157 RCTsAdults and children diagnosed with bronchiectasis based on plain-film chest radiography, bronchography, high-resolution computed tomography or physician diagnosis1107 (8-37)1 RCT, 6 crossover RCTsImmediate (within 24 h) and "long-term" (>24 h)
RCT: randomized controlled trial.

Representative recent RCTs follow. Trial characteristics and results are summarized in Tables 8 and 9. Gaps related to relevance, study design, and conduct are summarized in Tables 10 and 11.

Murray et al (2009) reported on a crossover study with 20 patients. The number of exacerbations did not differ statistically at 12 weeks.6, Cough-related QOL was significantly better after 12 weeks of any airway clearance technique compared with no airway clearance. Cochrane reviewers noted that the study was not blinded, and that patient-reported QOL measures may have been subject to bias.

Herrero-Cortina et al (2016) reported on a crossover RCT with 31 patients.7, The interventions were temporary PEP, autogenic drainage, and slow expiration with the glottis opened in the lateral position. There were no significant differences among treatments in the mean sputum clearance during the 24-hour period after each intervention, cough severity (measured using the total Leicester Cough Questionnaire score), or in lung function measures (eg, FEV1).

Table 8. Summary of Key RCT Characteristics
StudyCountriesSitesDatesParticipantsInterventions
ActiveComparator
Murray et al (2009)6,U.K.1NRPatients radiologically

diagnosed with bronchiectasis (n=20)

Acapella Choice (n=20)No chest

physical therapy (n=20)

Herrero-Cortina et al (2016)7,Spain12010-2013Patients radiologically

Diagnosed with bronchiectasis (n=31)

Slow expiration with glottis opened in lateral posture (n=31) and temporary PEP (n=31)Autogenic drainage (n=31)
NR: not reported; PEP: positive expiratory pressure; RCT: randomized controlled trial.

Table 9. Summary of Key RCT Outcomes
StudyTotal LCQ Score Difference24-h Sputum Volume Difference, mLNo. of Exacerbations
Median (IQR)Median (IQR)
Murray et al (2009)6,
20
20
Not applicable
Acapella
1.3 (-0.17-3.25)
2 (0-6)
5
No Acapella
0 (-1.5-0.5)
-1 (-5 to to 0)
7
p
0.002
0.02
0.48
Change (95% CI); pChange (95% CI)
Herrero-Cortina et al (2016)7,
Autogenic drainage
0.5 (0.1 to 0.5); 0.01
-1.4 (5.1 to 1.2)
Not studied
ELTGOL
0.9 (0.5 to 2.1); 0.001
-1.6 (-4.8 to1.0)
Not studied
TPEP
0.4 (0.1 to 1.2); 0.04
-2.5 (-8.6 to 0.1)
Not studied
pSee above
0.01
Not applicable
CI: confidence interval; ELTGOL: expiration with glottis opened in lateral posture; IQR: interquartile range; LCQ: Leicester Cough Questionnaire; RCT: randomized controlled trial; TPEP: temporary positive expiratory pressure.

Table 10. Relevance Gaps
StudyPopulationaInterventionbComparatorcOutcomesdFollow-Upe
Murray et al (2009)6,
Herrero-Cortina et al (2016)7,1, 2. Only 24-h follow-up is not enough
The evidence gaps stated in this table are those notable in the current review; this is not a comprehensive gaps assessment.
Population key: 1. Intended use population unclear; 2. Clinical context is unclear; 3. Study population is unclear; 4. Study population not representative of intended use.

bIntervention key: 1. Not clearly defined; 2. Version used unclear; 3. Delivery not similar intensity as comparator; 4.Not the intervention of interest.

c Comparator key: 1. Not clearly defined; 2. Not standard or optimal; 3. Delivery not similar intensity as intervention; 4. Not delivered effectively.

d Outcomes key: 1. Key health outcomes not addressed; 2. Physiologic measures, not validated surrogates; 3. No CONSORT reporting of harms; 4. Not establish and validated measurements; 5. Clinical significant difference not prespecified; 6. Clinical significant difference not supported.

e Follow-Up key: 1. Not sufficient duration for benefit; 2. Not sufficient duration for harms.

Table 11. Study Design and Conduct Gaps
StudyAllocationaBlindingbSelective
Reportingd
Follow-UpePowerdStatisticalf
Murray et al (2009)6,3. Allocation concealment unclear1. Not blinded to treatment assignment

2. Not blinded outcome assessment

3. Outcome assessed by treating physician

3. Power not based on clinically important difference
Herrero-Cortina et al (2016)7,1. Not blinded to treatment assignment

2. Not blinded outcome assessment

3. Outcome assessed by treating physician

1. Power calculations not reported

2. Power not calculated for primary outcome

3. Power not based on clinically important difference

The evidence gaps stated in this table are those notable in the current review; this is not a comprehensive gaps assessment.

Allocation key: 1. Participants not randomly allocated; 2. Allocation not concealed; 3. Allocation concealment unclear; 4. Inadequate control for selection bias.

bBlinding key: 1. Not blinded to treatment assignment; 2. Not blinded outcome assessment; 3. Outcome assessed by treating physician.

c Selective Reporting key: 1. Not registered; 2. Evidence of selective reporting; 3. Evidence of selective publication.

d Follow-Up key: 1. High loss to follow-up or missing data; 2. Inadequate handling of missing data; 3. High number of crossovers; 4. Inadequate handling of crossovers; 5. Inappropriate exclusions; 6. Not intent to treat analysis (per protocol for noninferiority trials).

e Power key: 1. Power calculations not reported; 2. Power not calculated for primary outcome; 3. Power not based on clinically important difference; 4. Target sample size not achieved.

f Statistical key: 1. Intervention is not appropriate for outcome type: (a) continuous; (b) binary; (c) time to event; 2. Intervention is not appropriate for multiple observations per patient; 3. Confidence intervals and/or p values not reported; 4.Comparative treatment effects not calculated.

Section Summary: Bronchiectasis

A 2015 systematic review identified 7 small RCTs assessing several types of oscillatory devices; only one reported the clinically important outcomes exacerbations or hospitalizations. Three reported on QOL, and trial findings were mixed. A 2016 crossover RCT did not find a significant benefit of temporary PEP compared with other airway clearance techniques.

Chronic Obstructive Pulmonary Disease

At least 2 systematic reviews have evaluated studies of airway clearance techniques in patients with COPD.8,9, Both reviews addressed various techniques (ie, they were not limited to studies on oscillatory devices) and are summarized in Table 12. Studies included in both the systematic reviews were largely small and none conducted a meta-analysis. Reviewers noted that quality of evidence was generally poor.9,

Table 12. Characteristics of Systematic Reviews
StudyDatesTrialsParticipantsN (Range)DesignDuration
Ides et al (2011)81980-200826Patients with COPD659 (7-58)Not reportedUnclear
Osadnik et al (2012)9,•Inception to 2009 (PEDro)

•Inception to 2011 (CAGR)

28Participants with investigator-defined COPD, emphysema or chronic bronchitis907 (5-96)RCTs (parallel and crossover)24 h to >8 wk
CAGR: Cochrane Airways Group Specialised Register of trials; COPD: chronic obstructive pulmonary disease;PEDro: Physiotherapy Evidence Database; RCT: randomized controlled trial.

Representative recent RCTs follow. Trial characteristics and results are summarized in Tables 13 and 14. Gaps related to relevance, study design and conduct are summarized in Tables 15 and 16.

Chakrovorty et al (2011) reported results of a crossover RCT among patients with moderate-to-severe COPD and mucus hypersecretion.10, Patients received HFCWO or conventional treatment in random order, for 4 weeks, with a 2-week washout period between treatments. The primary outcome was QOL as measured using the St. George's Respiratory Questionnaire (SGRQ). Only 1 of 4 dimensions of the SGRQ (the symptom dimension) improved after HFCWO compared with baseline, with a decrease in mean score from 72 to 64 (p=0.02). None of the 4 SGRQ dimensions improved after conventional treatment. There was no significant pre- to posttreatment differences in secondary outcomes (eg, FEV1, FVC).

Svenningsen et al (2016) reported on results of an unblinded, industry-funded, randomized crossover study.11, Each intervention period lasted 21 to 28 days. In the nonsputum producers, scores differed significantly only on the Patient Evaluation Questionnaire total score. In patients who were sputum-producers at baseline, pre- vs post-PEP scores differed significantly for FVC, 6-minute walk distance, SGRQ total score, and the Patient Evaluation Questionnaire ease of bringing up sputum and patient global assessment subscales. It is unclear if the interventions were clinically meaningful. The crossover studies had similar limitations including no between-group comparisons (ie, outcomes after oscillatory device use vs the control intervention), lack of intention-to-treat analysis, and short-term follow-up (immediate posttreatment period).

Goktalay et al (2013) reported on the results of a parallel-group RCT.12 Patients were randomized to 5 days of treatment with medical therapy plus HFCWO (n=25) or medical therapy only (n=25). At day 5, outcomes including FEV1, modified Medical Research Council dyspnea scale scores, and the 6-minute walk distance, did not differ significantly between groups. This short-term trial included hospitalized patients who might differ from COPD patients treated on an outpatient basis.

Table 13. Summary of Key RCT Characteristics
StudyCountriesSitesDatesParticipantsInterventions
ActiveComparator
Chakrovorty et al (2011)10,U.K.1NRPatients with at least 1 COPD exacerbation with FEV1 <0.8, FEV1/FVC <0.7, and a daily wet

sputum volume of >25 mL (n=38)

SmartVest Airway Clearance System (n=22)No SmartVest Airway Clearance System (n=22)
Svenningsen et al (2016)11,Canada1NRCOPD patients self-identified as sputum-producers or non-sputum-producers (n=32)Oscillatory PEP (AerobiKA device) (n=27)No oscillatory PEP (n=27)
Goktalay et al (2013)12Turkey12009-2011Patients with stage 3 or 4 COPD hospitalized for COPD exacerbations (n=50)HFCWO plus medical Tx (n=25)Medical Tx only (n=25)
COPD: chronic obstructive pulmonary disease; FEV1: forced expiratory volume in 1 second; FVC: forced vital capacity; HFCWO: high-frequency chest wall oscillation; NR: not reported; PEP: positive expiratory pressure; RCT: randomized controlled trial; Tx: treatment.

Table 14. Summary of Key RCT Outcomes
StudySGRO Total ScoresBODE Index
Chakrovorty et al (2011)10,
SmartVestBaseline: 63 End of treatment: 60Not assessed
No SmartVestBaseline: 62 End of treatment:62Not assessed
pNSNot applicable
Svenningsen et al (2016)11,
Oscillatory positive expiratory pressureSputum-producers: 40 (12)

Non-sputum-producers: 36

Not assessed
ControlSputum-producers: 49Non-sputum-producers:35Not assessed
p0.01 (sputum-producers)

0.64 (non-sputum-producers)

Not applicable
Goktalay et al (2013)12
HFCWO plus medical treatmentNot assessedDay 0: 7.72 Day 3: 7.00Day 5: 6.44
Medical treatment onlyNot assessedDay 0: 7.72 Day 3: 7.48Day 5: 7.24
pNot applicableUninterpretable
BODE: body mass index, airflow obstruction, dyspnea, and exercise; HFCWO: high-frequency chest wall oscillation; RCT: randomized controlled trial; SGRO: St George's Respiratory Questionnaire.

Table 15. Relevance Gaps
StudyPopulationaInterventionbComparatorcOutcomesdFollow-Upe
Chakrovorty et al (2011)10,
Svenningsen et al (2016)11,
Goktalay et al (2013)121. Not sufficient duration for benefits (short-term follow-up for 5 d)
The evidence gaps stated in this table are those notable in the current review; this is not a comprehensive gaps assessment.
Population key: 1. Intended use population unclear; 2. Clinical context is unclear; 3. Study population is unclear; 4. Study population not representative of intended use.

bIntervention key: 1. Not clearly defined; 2. Version used unclear; 3. Delivery not similar intensity as comparator; 4.Not the intervention of interest.

c Comparator key: 1. Not clearly defined; 2. Not standard or optimal; 3. Delivery not similar intensity as intervention; 4. Not delivered effectively.

d Outcomes key: 1. Key health outcomes not addressed; 2. Physiologic measures, not validated surrogates; 3. No CONSORT reporting of harms; 4. Not establish and validated measurements; 5. Clinical significant difference not prespecified; 6. Clinical significant difference not supported.

e Follow-Up key: 1. Not sufficient duration for benefit; 2. Not sufficient duration for harms.

Table 16. Study Design and Conduct Gaps
StudyAllocationaBlindingbSelective ReportingdFollow-UpePowerdStatisticalf
Chakrovorty et al (2011)10,3. Allocation concealment unclear1. Not blinded to treatment assignment

2. Not blinded outcome assessment

3. Outcome assessed by treating physician

1. High loss to follow-up or missing data: 8 out of 30 withdrew due to COPD exacerbations2. Power not calculated for primary outcome
Svenningsen et al (2016)11,3. Allocation concealment unclearNot blinded to treatment assignment1. High loss to follow-up or missing data: 16% withdrew from trial2. Power not calculated for primary outcome
Goktalay et al (2013)121. Participants not randomly allocated

2. Allocation not concealed

1. Not blinded to treatment assignment

2. Not blinded outcome assessment

3. Outcome assessed by treating physician

1. Power calculations not reported

2. Power not calculated for primary outcome

3. Power not based on clinically important difference

The evidence gaps stated in this table are those notable in the current review; this is not a comprehensive gaps assessment.

COPD: chronic obstructive pulmonary disease.
Allocation key: 1. Participants not randomly allocated; 2. Allocation not concealed; 3. Allocation concealment unclear; 4. Inadequate control for selection bias.

bBlinding key: 1. Not blinded to treatment assignment; 2. Not blinded outcome assessment; 3. Outcome assessed by treating physician.

c Selective Reporting key: 1. Not registered; 2. Evidence of selective reporting; 3. Evidence of selective publication.

d Follow-Up key: 1. High loss to follow-up or missing data; 2. Inadequate handling of missing data; 3. High number of crossovers; 4. Inadequate handling of crossovers; 5. Inappropriate exclusions; 6. Not intent to treat analysis (per protocol for noninferiority trials).

e Power key: 1. Power calculations not reported; 2. Power not calculated for primary outcome; 3. Power not based on clinically important difference; 4. Target sample size not achieved.

f Statistical key: 1. Intervention is not appropriate for outcome type: (a) continuous; (b) binary; (c) time to event; 2. Intervention is not appropriate for multiple observations per patient; 3. Confidence intervals and/or p values not reported; 4.Comparative treatment effects not calculated.

Section Summary: Chronic Obstructive Pulmonary Disease

Only a few controlled studies have evaluated oscillatory devices for the treatment of COPD, and they tended to use intention-to-treat analysis and between-group comparisons. The published studies reported mixed findings and did not support the use of oscillatory devices in COPD patients.

Respiratory Conditions Related to Neuromuscular Disorders

Children

A Cochrane review by Winfield et al (2014) evaluated the nonpharmacologic management of respiratory morbidity in children with severe global developmental delay treated with airway clearance techniques.12, Reviewers included RCTs and nonrandomized comparative studies. They identified 3 studies on HFCWO (1 RCT, 2 pre-post) and one on PEP (pre-post), with sample sizes from 15 and 28 patients. As a result of heterogeneity, a meta-analysiswas not conducted. It is summarized in Table 17.

Table 17. Characteristics of Systematic Reviews
StudyDatesTrialsParticipantsN (Range)DesignDuration
Winfield et al (2014)12,Inception to Nov 201315Children up to 18 y with a diagnosis of severe neurologic impairment and respiratory morbidityNot reportedRCTs and nonrandomized comparative studiesUnclear
RCT: randomized controlled trial.

Representative recent RCTs follow. Trial characteristics and results are summarized in Tables 18 and 19. Gaps related to relevance, study design and conduct are summarized in Tables 20 and 21.

Yuan et al (2010) reported results of a parallel-arm RCT.13, Both groups were instructed to perform the assigned treatment for 12 minutes, 3 times a day for the study period (mean, 5 months). There were no statistically significant differences between groups on primary outcomes. No therapy-related adverse events were reported in either group.

Lange et al (2006) reported on results of a parallel-arm RCT in adults with amyotrophic lateral sclerosis.14, Patients were randomized to 12 weeks of HCFWO or usual care. There were no statistically significant between-group differences in pulmonary measures (FVC predicted, capnography, oxygen saturation, or peak expiratory flow). There was also no significant difference in the amyotrophic lateral sclerosis Functional Rating Scale respiratory subscale score (worsening) at 12 weeks. Of symptoms assessed as secondary outcomes, there was significantly less breathlessness and night cough in the HCFWO group than in the usual care group, and groups did not differ significantly on other symptoms, including the noise of breathing, suction frequency, suction amount, day cough, and nocturnal symptoms.

Table 18. Summary of Key RCT Characteristics
StudyCountriesSitesDatesParticipantsInterventions
ActiveComparator
Yuan et al (2010)13,U.S.1NRPatients with cerebral palsy or neuromuscular disease attending a pediatric pulmonary clinic (n=28)HCFWO (n=12)Standard chest physical therapy (n=11)
Lange et al (2006)14,U.S.6NRAdults with amyotrophic lateral sclerosis (n=46).HCFWO (n=22)No treatment (n=24)
HFCWO: high-frequency chest wall oscillation; NR: not reported; RCT: randomized controlled trial.

Table 19. Summary of Key RCT Outcomes
StudyHospitalization/IV AntibioticsTDI (proportion showing worsening)
Yuan et al (2010)13,
23
HCFWO
0/12
Not assessed
Standard chest physical therapy
4/11
Not assessed
p
0.09
Not applicable
Lange et al (2006)14,
-
18
HCFWONot assessedFunctional impairment: 27.8%

Magnitude of task: 38.9%

Magnitude of effort: 27.8%

No treatmentNot assessedFunctional impairment: 43.8%

Magnitude of task: 50%

Magnitude of effort: 56.2%

pNot applicableFunctional impairment: 0.331

Magnitude of task: 0.515

Magnitude of effort: 0.092

HFCWO: high- frequency chest wall oscillation; IV: intravenous; RCT: randomized controlled trial; TDI:Transitional Dyspnea Index

Table 20. Relevance Gaps
StudyPopulationaInterventionbComparatorcOutcomesdFollow-Upe
Yuan et al (2010)13,
Lange et al (2006)14,
The evidence gaps stated in this table are those notable in the current review; this is not a comprehensive gaps assessment.
Population key: 1. Intended use population unclear; 2. Clinical context is unclear; 3. Study population is unclear; 4. Study population not representative of intended use.

bIntervention key: 1. Not clearly defined; 2. Version used unclear; 3. Delivery not similar intensity as comparator; 4.Not the intervention of interest.

c Comparator key: 1. Not clearly defined; 2. Not standard or optimal; 3. Delivery not similar intensity as intervention; 4. Not delivered effectively.

d Outcomes key: 1. Key health outcomes not addressed; 2. Physiologic measures, not validated surrogates; 3. No CONSORT reporting of harms; 4. Not establish and validated measurements; 5. Clinical significant difference not prespecified; 6. Clinical significant difference not supported.

e Follow-Up key: 1. Not sufficient duration for benefit; 2. Not sufficient duration for harms.

Table 21. Study Design and Conduct Gaps
StudyAllocationaBlindingbSelective ReportingdFollow-UpePowerdStatisticalf
Yuan et al 2010)13,1. Allocation concealment unclear1. Not blinded to treatment assignment

2. Not blinded outcome assessment (except chest X-rays)

3. Outcome assessed by treating physician

1. High loss to follow-up or missing data 12% missing data and all in treatment group1, 2, 3. Trial was exploratory and was not powered to detect statistically significant findings on of the primary outcomes
Lange et al (2006)14,1. Allocation not concealed1. Not blinded to treatment assignment

2. Not blinded outcome assessment

3. Outcome assessed by treating physician

1. High loss to follow-up or missing data 15% missing data at 12 wk2. Power not calculated for primary outcome

3. Power not based on clinically important difference

The evidence gaps stated in this table are those notable in the current review; this is not a comprehensive gaps assessment.

HFCWO: high-frequency chest wall oscillation.
Allocation key: 1. Participants not randomly allocated; 2. Allocation not concealed; 3. Allocation concealment unclear; 4. Inadequate control for selection bias.

bBlinding key: 1. Not blinded to treatment assignment; 2. Not blinded outcome assessment; 3. Outcome assessed by treating physician.

c Selective Reporting key: 1. Not registered; 2. Evidence of selective reporting; 3. Evidence of selective publication.

d Follow-Up key: 1. High loss to follow-up or missing data; 2. Inadequate handling of missing data; 3. High number of crossovers; 4. Inadequate handling of crossovers; 5. Inappropriate exclusions; 6. Not intent to treat analysis (per protocol for noninferiority trials).

e Power key: 1. Power calculations not reported; 2. Power not calculated for primary outcome; 3. Power not based on clinically important difference; 4. Target sample size not achieved.

f Statistical key: 1. Intervention is not appropriate for outcome type: (a) continuous; (b) binary; (c) time to event; 2. Intervention is not appropriate for multiple observations per patient; 3. Confidence intervals and/or p values not reported; 4.Comparative treatment effects not calculated.

Section Summary: Respiratory Conditions Related to Neuromuscular Disorders

Two RCTs and a systematic review have evaluated oscillatory devices for treatment of respiratory conditions in neuromuscular disorders. One RCT was not powered to detect statistical significance. The other, conducted in amyotrophic lateral sclerosis patients, did not find statistically significant improvement after HCFWO compared with usual care for the primary outcomes (pulmonary function measures) or most secondary outcomes.

Summary of Evidence

For individuals who have cystic fibrosis who receive oscillatory devices, the evidence includes RCTs and a systematic review. Relevant outcomes are symptoms, quality of life, hospitalizations, and medication use. The RCTs reported mixed findings and limitations such as small sample sizes and large dropout rates. A systematic review identified 35 RCTs comparing oscillatory devices with another recognized airway clearance techniques; some were published only as abstracts. Reviewers could not pool findings due to heterogeneity in study designs and outcome measures and concluded that additional adequately powered RCTs with long-term follow-up would be needed to make conclusions about oscillatory devices for cystic fibrosis. The evidence is insufficient to determine the effects of the technology on health outcomes.

For individuals who have bronchiectasis who receive oscillatory devices, the evidence includes RCTs and a systematic review. Relevant outcomes are symptoms, quality of life, hospitalizations, and medication use. A 2015 systematic review identified 7 small RCTs on several types of oscillatory devices; only one reported the clinically important outcomes of exacerbations or hospitalizations. Only 3 RCTs reported on quality of life, and findings were mixed. The evidence is insufficient to determine the effects of the technology on health outcomes.

For individuals who have chronic obstructive pulmonary disease who receive oscillatory devices, the evidence includes RCTs and systematic reviews. Relevant outcomes are symptoms, quality of life, hospitalizations, and medication use. Only a few controlled studies have evaluated oscillatory devices for the treatment of chronic obstructive pulmonary disease, and they tend to have small sample sizes, short follow-up periods, and limitations in their analyses (eg, lack of intention-to-treat analysis and between-group comparisons). Moreover, the published studies reported mixed findings and did not clearly support the use of oscillatory devices in this population. The evidence is insufficient to determine the effects of the technology on health outcomes.

For individuals who have respiratory conditions related to neuromuscular disorders who receive oscillatory devices, the evidence includes 2 RCTs and a systematic review. Relevant outcomes are symptoms, quality of life, hospitalizations, and medication use. One of the RCTs was not powered to detect statistically significant differences. The other RCT, conducted in patients with amyotrophic lateral sclerosis, did not find significant improvements after high-frequency chest wall compression devices vs usual care in primary outcomes, in pulmonary function measures, or in most secondary outcomes. The evidence is insufficient to determine the effects of the technology on health outcomes.

SUPPLEMENTAL INFORMATION

Clinical Input From Physician Specialty Societies and Academic Medical Centers

While the various physician specialty societies and academic medical centers may collaborate with and make recommendations during this process, through the provision of appropriate reviewers, input received does not represent an endorsement or position statement by the physician specialty societies or academic medical centers, unless otherwise noted.

In response to requests, input was received from 2 academic medical centers while this policy was under review in 2008. Input indicated the available studies demonstrated that these oscillatory devices are comparable with chest physical therapy for cystic fibrosis and bronchiectasis. The most commonly mentioned clinical criteria were patients who failed or were intolerant of other methods of mucus clearance and patients who lacked caregivers to provide chest physical therapy. Input did not support the use of oscillatory devices for treatment of chronic obstructive pulmonary disease.

Practice Guidelines and Position Statements

American College of Chest Physicians

The 2006 guidelines from the American College of Chest Physicians recommended (level of evidence: low) that, in patients with cystic fibrosis, devices designed to oscillate gas in the airway, either directly or by compressing the chest wall, can be considered as an alternative to chest physical therapy.15,

Cystic Fibrosis Foundation

The Cystic Fibrosis Foundation (2009) published guidelines on airway clearance therapies based on a systematic review of evidence.16, The Foundation recommended airway clearance therapies for all patients with cystic fibrosis but stated that no therapy had been demonstrated to be superior to others (level of evidence: fair; net benefit: moderate; grade of recommendation: B).

U.S. Preventive Services Task Force Recommendations

Not applicable.

Ongoing and Unpublished Clinical Trials

Some currently unpublished trials that might influence this review are listed in Table 22.

Table 22. Summary of Key Trials
NCT No.Trial NamePlanned EnrollmentCompletion Date
Ongoing
NCT03013452Oscillating PEP vs Autogenic Drainage in People With Bronchiectasis (oPEP-vs-AD)
50
Dec 2018*
NCT: national clinical trial.
* No results posted on clinicaltrials.gov website as of 05/10/19.]

________________________________________________________________________________________

Horizon BCBSNJ Medical Policy Development Process:

This Horizon BCBSNJ Medical Policy (the “Medical Policy”) has been developed by Horizon BCBSNJ’s Medical Policy Committee (the “Committee”) consistent with generally accepted standards of medical practice, and reflects Horizon BCBSNJ’s view of the subject health care services, supplies or procedures, and in what circumstances they are deemed to be medically necessary or experimental/ investigational in nature. This Medical Policy also considers whether and to what degree the subject health care services, supplies or procedures are clinically appropriate, in terms of type, frequency, extent, site and duration and if they are considered effective for the illnesses, injuries or diseases discussed. Where relevant, this Medical Policy considers whether the subject health care services, supplies or procedures are being requested primarily for the convenience of the covered person or the health care provider. It may also consider whether the services, supplies or procedures are more costly than an alternative service or sequence of services, supplies or procedures that are at least as likely to produce equivalent therapeutic or diagnostic results as to the diagnosis or treatment of the relevant illness, injury or disease. In reaching its conclusion regarding what it considers to be the generally accepted standards of medical practice, the Committee reviews and considers the following: all credible scientific evidence published in peer-reviewed medical literature generally recognized by the relevant medical community, physician and health care provider specialty society recommendations, the views of physicians and health care providers practicing in relevant clinical areas (including, but not limited to, the prevailing opinion within the appropriate specialty) and any other relevant factor as determined by applicable State and Federal laws and regulations.

___________________________________________________________________________________________________________________________

Index:
Oscillatory Devices for the Treatment of Cystic Fibrosis and Other Respiratory Disorders
ABI Vest
Acapella Device
Advanced Respiratory Modified Vest
Cystic Fibrosis, Oscillatory Devices
Flutter Device
High Frequency Chest Compression
Intrapulmonary Percussive Ventilation (IPV)
IPV (Intrapulmonary Percussive Ventilation)
Mechanical Percussive Devices for Cystic Fibrosis and Certain Other Lung Diseases
MedInnovation's RespIn 11 Bronchial Clearance System
Modified Vest Airway Clearance System
Percussionaire
RespIn 11 Bronchial Clearance System
ThAIRapy Bronchial Drainage System
Vest Percussor
Vibralung Acoustical Percussor

References:
1. Morrison L, Agnew J. Oscillating devices for airway clearance in people with cystic fibrosis. Cochrane Database Syst Rev. 2014;7:CD006842. PMID 25038719.

2. McIlwaine MP, Alarie N, Davidson GF, et al. Long-term multicentre randomised controlled study of high frequency chest wall oscillation versus positive expiratory pressure mask in cystic fibrosis. Thorax. Aug 2013;68(8):746-751. PMID 23407019.

3. Pryor JA, Tannenbaum E, Scott SF, et al. Beyond postural drainage and percussion: Airway clearance in people with cystic fibrosis. J Cyst Fibros. May 2010;9(3):187-192. PMID 20153269.

4. Sontag MK, Quittner AL, Modi AC, et al. Lessons learned from a randomized trial of airway secretion clearance techniques in cystic fibrosis. Pediatr Pulmonol. Mar 2010;45(3):291-300. PMID 20146387.

5. Lee AL, Burge AT, Holland AE. Airway clearance techniques for bronchiectasis. Cochrane Database Syst Rev. Nov 23 2015;11(11):CD008351. PMID 26591003.

6. Murray MP, Pentland JL, Hill AT. A randomised crossover trial of chest physiotherapy in non-cystic fibrosis bronchiectasis. Eur Respir J. Nov 2009;34(5):1086-1092. PMID 19541717.

7. Herrero-Cortina B, Vilaro J, Marti D, et al. Short-term effects of three slow expiratory airway clearance techniques in patients with bronchiectasis: a randomised crossover trial. Physiotherapy. Dec 2016;102(4):357-364. PMID 26712530.

8. Ides K, Vissers D, De Backer L, et al. Airway clearance in COPD: need for a breath of fresh air? A systematic review. COPD. Jun 2011;8(3):196-205. PMID 21513439.

9. Osadnik CR, McDonald CF, Jones AP, et al. Airway clearance techniques for chronic obstructive pulmonary disease. Cochrane Database Syst Rev. Mar 14 2012;3(3):CD008328. PMID 22419331.

10. Chakravorty I, Chahal K, Austin G. A pilot study of the impact of high-frequency chest wall oscillation in chronic obstructive pulmonary disease patients with mucus hypersecretion. Int J Chron Obstruct Pulmon Dis. 2011;6:693-699. PMID 22259246.

11. Svenningsen S, Paulin GA, Sheikh K, et al. Oscillating positive expiratory pressure therapy in chronic obstructive pulmonary disease and bronchiectasis. COPD. Feb 2016;13(1):66-74. PMID 26430763.

12. Winfield NR, Barker NJ, Turner ER, et al. Non-pharmaceutical management of respiratory morbidity in children with severe global developmental delay. Cochrane Database Syst Rev. Oct 19 2014;10(10):CD010382. PMID 25326792.

13. Yuan N, Kane P, Shelton K, et al. Safety, tolerability, and efficacy of high-frequency chest wall oscillation in pediatric patients with cerebral palsy and neuromuscular diseases: an exploratory randomized controlled trial. J Child Neurol. Jul 2010;25(7):815-821. PMID 20357238.

14. Lange DJ, Lechtzin N, Davey C, et al. High-frequency chest wall oscillation in ALS: an exploratory randomized, controlled trial. Neurology. Sep 26 2006;67(6):991-997. PMID 17000967.

15. McCool FD, Rosen MJ. Nonpharmacologic airway clearance therapies: ACCP evidence-based clinical practice guidelines. Chest. Jan 2006;129(1 Suppl):250S-259S. PMID 16428718.

16. Flume PA, Robinson KA, O'Sullivan BP, et al. Cystic fibrosis pulmonary guidelines: airway clearance therapies. Respir Care. Apr 2009;54(4):522-537. PMID 19327189.

Codes:
(The list of codes is not intended to be all-inclusive and is included below for informational purposes only. Inclusion or exclusion of a procedure, diagnosis, drug or device code(s) does not constitute or imply authorization, certification, approval, offer of coverage or guarantee of payment.)

CPT*

HCPCS

    A7025
    A7026
    E0480
    E0481
    E0483
    E0484
    S8185

* CPT only copyright 2019 American Medical Association. All rights reserved. CPT is a registered trademark of the American Medical Association.

_________________________________________________________________________________________

Medical policies can be highly technical and are designed for use by the Horizon BCBSNJ professional staff in making coverage determinations. Members referring to this policy should discuss it with their treating physician, and should refer to their specific benefit plan for the terms, conditions, limitations and exclusions of their coverage.

The Horizon BCBSNJ Medical Policy Manual is proprietary. It is to be used only as authorized by Horizon BCBSNJ and its affiliates. The contents of this Medical Policy are not to be copied, reproduced or circulated to other parties without the express written consent of Horizon BCBSNJ. The contents of this Medical Policy may be updated or changed without notice, unless otherwise required by law and/or regulation. However, benefit determinations are made in the context of medical policies existing at the time of the decision and are not subject to later revision as the result of a change in medical policy

____________________________________________________________________________________________________________________________